This clearance shouldn't be ignored
as it's required for ventilation system
of the appliance to operate.
Right Place For Installation
Product has been designed to be mounted
to worktops procured from market. a safe
distance must be left between the product and
kitchen walls or furniture. See the drawings
provided on pages 119-120 for proper
distances (values in mm).
Z
Z
Used surfaces, synthetic laminates and
adhesives must be heat resistant
(minimum 100 °C).
Z
Z
Kitchen cupboards must be level with
product and secured.
Z
Z
If there is a drawer below the oven, a rack
must be placed between oven and drawer.
WARNING: Do not install the product next
to refrigerators or coolers. The heat emitted by
the product increases the energy consumption
of cooling devices.
WARNING: Do not use door and/or handle
to carry or move the product.
45 cm Built-In Oven Installation and
Mounting
Place of use for product must be located
before starting installation. Product mustn't
be installed in places which are under
the effect of strong air flow. Carry the product
with minimum two people. Do not drag
the product so that floor isn't damaged.
Remove all transportation materials inside and
outside the product. Remove all materials and
documents in the product.
Installation Under Counter
(figure 1 page 119)
Cabin must match the dimensions provided
in figure 2 (page 119).
A clearance must be provided at the rear
part of the cabin as indicated in the figure so
that necessary ventilation can be achieved.
After mounting, the clearance between lower
and upper part of the counter is indicated
in figure 6 (page 120) with „A". It's for
ventilation and shouldn't be covered.
FMO 45 GN 81 / FMO 45 GN 86
Installation in an Elevated Cabinet
(figure 4 page 120)
Cabin must match the dimensions provided
in figure 5 (page 120). The clearances with
the dimensions indicated in the figure must
be provided at the rear part of cabin, upper and
lower sections so that necessary ventilation
can be achieved.
Installation Requirements
Product dimensions are provided
in the figure 3 (page 119). Furniture surfaces
for mounting and mounting materials
to be usedmust have a minimum temperature
resistance of 100 °C. Mounting cabin must
be secured and its floor must be plane for
product not to tilt over. Cabin floor must have
a minimum strength that would handle
a load of 60 kg.
Placing and Securing the Oven
X
Z
X
Z
X
Z
X
Z
X
Z
Electrical Connection
Mounting place of the product must have
appropriate electrical installation.
Network voltage must be compatible with
the values provided on type label of product.
Product connection must be made
in accordance with local and national
electrical requirements. Before starting
the mounting disconnect network power.
Do not connect the product to network until
its mounting is completed.
– 10 –
Place the oven into the cabin with two
or more people.
Ensure that oven's frame and front edge
of the furniture match uniformly.
Supply cord mustn't be under the oven,
squeeze in between oven and furniture
or bend.
Fix the oven to the furniture by using
the screws provided with the product.
Screws must be mounted as shown
in figure 6 (page 120) by passing them
through plastics attached to frame
of the product.
Screws mustn't be overtightened.
Otherwise, screw sockets might
be worn. Check that oven doesn't
move after mounting. if oven
isn't mounted in accordance with
instructions, there is a risk of tilt over
during operation.