"VIRTUAL MIDNIGHT" INSTRUCTIONS
ISTRUZIONI "VIRTUAL MIDNIGHT"
INSTRUCTIONS "VIRTUAL MIDNIGHT"
ANLEITUNG FÜR "VIRTUAL MIDNIGHT"
INSTRUCCIONES "VIRTUAL MIDNIGHT"
Made in Italy
38W per beam / per emissione - 230Vac
"VIRTUAL MIDNIGHT" FUNCTION
The card controls a power supply unit with 1–10V input for regulating a power supply unit. It records the operating time of the previous nights and uses this to create the rules that will
be used on the current night, in accordance with the graph below:
Output
NIGHT
100%
U1
T1
ON
MD
T1
T2
Definition of the terms used:
ON indicates the moment the card is powered.
L1 = duration of the previous night.
L2 = duration of the night prior to that.
L3 = duration of the night three nights earlier.
L4 = duration of the night four nights earlier.
The nights are memorised only if their duration is greater than 3 hours and less than 18 hours.
MD is the length of half the virtual night, and is calculated based on the following rules:
–
if there are no valid nights recorded in the memory, MD time = infinite
–
if there is only 1 valid night (L1) recorded in the memory, MD time = L1/2
–
if there are 2 valid nights (L1 and L2) recorded in the memory, MD time = (3xL1+L2)/8
–
if there are 3 valid nights (L1, L2 and L3) recorded in the memory, MD time = (2xL1+L2+L3)/8
–
if there are 4 valid nights (L1, L2, L3 and L4) recorded in the memory, MD time = (L1+L2+L3+L4)/8
T1: output variation time from 100% to U1 value, default = 0 h.
T2: output variation time from U1 value to 100%, default = 9 h.
ΔT1 and ΔT2: transition time = 10 min.
U1: output status during the middle of the night (from T1 to T2), default = 30%.
Programming:
Default T1 time=0 hours, T2=9 hours and U1=30%. It is possible to reprogram these values using the appropriate sequence of ON/OFF of 230Vac mains power. T1 and T2 will have a
duration in minutes equal to the duration in seconds of programming, while U1 will have a percentage value equal to the duration in seconds of programming.
230Vac
OUT
To access the programming, perform the sequence:
ON-OFF-ON-OFF-ON-OFF-ON with an 'ON' state no greater than 5 seconds, after which the output will start to flash to indicate ready-to-program status; perform a new OFF-ON to
start setting the T1 value: every second in ON corresponds to a minute in T1 state; once the desired value has been reached, perform an OFF-ON again and start setting the T2 values,
bearing in mind again that every second passed will correspond to 1 minute; once the desired value has been reached, perform an OFF-ON again and start setting the U1 value: in this
case every second in ON corresponds to 1%; once the desired value has been reached, perform an OFF-ON again. At this point, the output will reproduce the parameters that have
just been set: it will activate for the T1 time that has just been set, at the end of which it will switch off then come back on for the T2 that has just been set. Ditto for the U1 value; after
which the data will be saved.
If the user does not perform any operation during the phase "ready for programming", the card will leave the programming mode; if the user switches off and back on while the program
is being displayed, the card will leave the programming mode and the data will not be saved.
The maximum value that can be recorded for T1 and T2 is 540 seconds (equal to 540 minutes), while the maximum value for U1 is 80 seconds (equal to 80%).
FUNZIONE "VIRTUAL MIDNIGHT"
Il dispositivo installato controlla la regolazione dell'alimentatore integrato. Viene registrato il tempo di funzionamento delle notti precedenti e lo si utilizza per creare le regole che ver-
ranno utilizzate nella notte in corso, secondo il seguente grafico:
Output
NIGHT
100%
U1
T1
ON
MD
T1
T2
Definizione dei termini utilizzati:
ON indica il momento di alimentazione della scheda.
L1 = durata dell'ultima notte trascorsa.
L2 = durata della penultima notte trascorsa.
L3 = durata della terzultima notte trascorsa.
L4 = durata della quartultima notte trascorsa.
Le notti vengono memorizzate solo se il loro tempo è maggiore di 3 ore e minore di 18 ore.
MD è il tempo della metà della notte virtuale, e viene calcolata secondo queste regole:
L&L Luce&Light srl / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04
Virtual Midnight (Siri Blvd 1.0 - 1.1 - 2.0 - 2.1 - 3.0)
Projectors
/
Proiettori
/
Projecteurs
/
Spots
Kg 4,60
IP66
Kg 8,20
T2
OFF Time
READY FOR
PROGRAMMING
PROGRAMMING
T1 1s = 1min
T2
OFF Time
E lucelight@lucelight.it / www.lucelight.it
/
Proyectores
Kg 6,00
Kg 4,00
Kg 10,8
PROGRAMMING
PROGRAMMING
DISPLAY T1
T2 1s = 1min
U1 1s = 1%
1s = 1min
IK06
DISPLAY T2
DISPLAY U1
1s = 1min
1s = 1%
English
Italiano
1/4