2
AUTOMATIC INFLATION MODEL
Inflates automatically within five seconds, upon immersion of the lifejacket. The automatic
lifejacket can also be activated manually by pulling on the activating cord at the lifejacket's
bottom right hand side
4
. The mouth inflation tube is also used to deflate the lifejacket. See Deflation.
MANUAL INFLATION MODEL
The manual lifejacket is activated manually by pulling on the activating cord at the lifejacket's bottom
right hand side
The mouth inflation tube is also used to deflate the lifejacket. See Deflation.
3
BEFORE USE
Follow the illustrated instructions on the label by the inflation mechanism.
CHECK THE CO
1.
the CO
into place (clockwise) by hand. Pierced CO
cylinder retaining strap over the cylinder.
Baltic Automatic Valve
2.
Baltic Automatic Valve
3.
jacket must be inspected and rearmed. Baltic Manual valve
lifejacket must be inspected and rearmed. Carefully follow the instructions on the next page or
12
in our rearming kit.
4
CHECK THE ACTIVATING CORD
4.
accessible without opening the lifejacket.
5
DEFLATION
The cap on the mouth inflation tube is turned upside down and gently pressed down into the tube
. Squeeze out the air. Replace the cap on the mouth inflation tube, in the normal position, be-
11
fore repacking. NOTE! Do not use any other object than the upside down cap to deflate the lifejacket.
REARMING
BEFORE REARMING
Please note that the following rearming instructions must be followed in order for the product
to function. If you are unsure whether the product is correctly assembled, please contact your
retailer or the manufacturer.
Only use a Baltic rearming kit.
•
Rearming must be carried out with dry hands, in dry surroundings and without tools.
•
Place the inflatable lifejacket, back downwards, on a flat surface.
•
Make sure that the inflatable lifejacket is emptied of all air and that the mouth inflation
•
tube's cap is in the normal position.
Follow the instructions in this manual and those in the instruction sheet accompanying
•
the rearming kit.
The product is ready for use only when it has been rearmed according to the instructions.
•
Follow the following instructions carefully.
•
BALTIC LIFEJACKETS – USER'S GUIDE
. The lifejacket can also be inflated using the mouth inflation tube
3
3
. The lifejacket can also be inflated using the mouth inflation tube
5
CYLINDER
2
cylinder (anticlockwise) and check that it is not pierced. Screw the unpierced CO
2
7
CHECK THAT THE CARTRIDGE IS IN DATE
If the green safety indicator clip is missing or damaged, the life-
7
Remove the cylinder retaining strap
.
cylinders are used and must be replaced. Refit the
2
9
10
Check that the activating cord runs freely and is
.
4
.
and unscrew
6
back
2
8
.
: If the indicator is red, the