Make sure that the temperature sensors are connected correctly.
•
Sensor cables and power cables must be separated to avoid interference. At any sign of
•
malfunction, turn the system off and only turn it back on when the problem has been fixed.
This device does not have a fuse to limit the current. If necessary, it is recommended to
•
install a separate fuse.
This document does not indicate all the precautions that must be taken at the time of
•
installation. The installation should be strictly done only by a qualified person.
Make sure during installation that there is a minimum space of 5 centimetres in
all directions so that good convection cooling can be guaranteed.
3.
Turning on
The device should only be switched on if the installation has been completed.
Please check the wiring again and make sure that no mistakes have been
made.
Power up is done by connecting the device to the mains.
When the device is turned on, it will immediately start controlling the temperature. When first
turned on, the device has the desired temperature of 0.0 ºC or 32 ºF set at the factory. If the actual
temperature is below this value, the load output will be switched on.
Once the desired temperature has been changed to another value, it will be stored in the memory.
When the device is switched on next time, this temperature will be the start temperature.
To know how to change the desired temperature and how to change the unit of measurement
between Celsius and Fahrenheit, see the next chapter.