Appendix B
AquaBoost Controller Drive Head Technical Data
AquaBoost
Controller
Type
Rated output
AV 1.1
1 HP
AV 1.15
2 HP
AV 1.2
3 HP
Input Voltage:
Output Voltage:
Max. Frequency:
Min. Frequency:
Electrical Efficiency:
Protection against:
A power supply filter is included to ensure interference immunity.
The AV Series frequency converter complies with the general EMV provisions and has been tested
according to the following standards:
• Radio Interference Suppression EN 50081 Part 2 and EN 50082 Part 2
• High Frequency Field Interference ENV 50140 and ENV 50141
• Static Electricity Discharge EN 61000-4
• Disturbance Voltage EN55011
Ambient Temperature:
Storage Temperature:
Humidity:
Air Pollution:
Controller Enclosure:
Approvals:
Altitude:
Supply
Voltage
1 x 230 V / 40-60 Hz
1 x 230 V / 40-60 Hz
1 x 230 V / 40-60 Hz
1 x 230 VAC ± 10% (An input line reactor is highly recommended
for areas which experience voltage fluctuation.)
3 x 230 Volt AC
40 – 60 Hz – selectable
0 - f-max
> 95%
Short circuit, under-voltage, overheating of the electronics (overload) and
additional protective functions via external switch (motor temperature,
low water).
5° C – 40° C
-25° C – +55° C
(+70° C during max. 24 hours)
rH maximum 50% at 40° C, unlimited
RH maximum 90% at 20° C, maximum 30 days per year
Condensation not permitted!
The air may contain dry dust as found in workshops where there is no
excessive quantity of dust due to machines. Excessive amounts of dust,
acids, corrosive gases, salts, etc. are not permitted.
NEMA 12, IP 55
UL, CUL, CE
Maximum 3000 feet above sea level. Consult factory for higher altitudes.
3 x 230 V
3 x 230 V
3 x 230 V
1
Motor
Voltage
Protection
4.8 A
10 Ampere
7.0 A
10 Ampere
10.0 A
16 Ampere