1. WARNING: Risk of fire. Do not use as a
residential or household heater.
2. Do not use outdoors.
3. This heater is not intended for use in bathrooms,
laundry areas, and similar indoor locations.
4. CAUTION:
Do not operate
attached.
The Hot One may sit on a floor surface or be mounted to the wall using the universal stand provided. If mounted on the
wall, maintain 6 inch minimum clearance from the top of the unit to the ceiling. The Hot One is not recommended for
ceiling mount. Recommended for elevations under 7500 feet.
Heater Inspection and Assembly
STEP 1
Thoroughly inspect your heater for any shipping or handling damage and remove any paper or packaging material found around the
heater.
Grounding Plug and Receptacle Requirements
STEP 2
This heater is for use on 240 volts. The cord has a 20 amp or 30 amp plug as shown in Figure 1. No adapter is available for these blade
configurations, and none should be used. The RCP requires a 240 volt grounded receptacle. When properly installed, it provides a
ground connection through the cord to the heater to protect the operator from electric shock. Do not use an extension cord, power strip
or any kind of adapter.
RCP502S - 30 Amp
Plug Configuration
Receptacle Configuration
NEMA #6-30R
Assembly
STEP 3
The universal stand is assembled as follows:
Floor Stand Assembly
1. Place steel washer, then rubber washer on each knob shaft
provided.
2. Screw each knob into the bracket found on both sides of the
heater, but do not tighten.
3. With heater sitting on a firm surface, slide the stand onto each
knob shaft between the steel and rubber washers (See Figure 2).
4. Tighten knobs.
Note: The heater must be operated with the stand attached to the
heater.
Wall Mount Assembly
1. Place steel washer, then rubber washer on each knob shaft
provided.
2. Screw each knob into the bracket found on both sides of the
heater, but do not tighten.
3. Mount stand to wall. The wall and mounting hardware must
be of adequate strength to support the heater. Note: A 240-volt
receptacle must be within six feet of the heater.
4. Slide the stand onto each knob shaft between the steel and
rubber washers (Figure 2).
5. Tighten knobs.
INSTALLATION INSTRUCTIONS
without stand
RCP402S - 20 Amp
Plug Configuration
Receptacle Configuration
NEMA #6-20R
Figure 1
5. Heater must be kept clear of all obstructions:
3 foot minimum clearance from front, 6 inch
minimum clearance from back and top, and 12
inch minimum clearance from sides. See Figure
3.
6. Always plug the heater directly into a 240 volt
wall receptacle. Never use an extension cord.
STAND
RUBBER
STEEL
WASHER
WASHER
KNOB
BRACKET
Figure 2
Figure 3
Page 3