CAUTION:
(1) When connecting the unit to
the propane gas make certain
the propane gas tank is
equipped with its own high pres-
sure regulator. In addition, a
pressure regulator was supplied
with the cooktop. This second
regulator must be installed with
the cooktop. The maximum gas
pressure to this appliance is not
to exceed 14.0 inches water col-
umn from the propane gas tank
regulator.
The following must be met when
testing supply piping system:
a) The appliance and its indi-
vidual shut-off valve must be dis-
connected from the gas supply
piping system at test pressures
in excess of 1/2 psig (3.5 kPa).
b) The appliance must be iso-
lated from the gas supply piping
system by closing its individual
manual shut-off valve during any
pressure testing of the gas sup-
ply piping system at test pres-
sures equal to or less than 1/2
psig (3.5 kPa).
2
Kit Contents:
Conversion Kit Instructions
Conversion Sticker
Foam Tape
5 LP Orifices (1-74/ 2-89/ 2-97)
5 Venturis (10.5 mm)
ORIFICE and VENTURI PACKAGE
TOP
BOTTOM
Tools Required:
7 mm Socket Driver w/ 3" extension
20 mm Socket or Wrench
Adjustable Wrench
Flat-head Screwdriver (small)
Main Orifices 4 Burner:
#97 - Front Left - 10,500 Btu/h
#89 - Rear Left - 8,500 Btu/h
#74 - Front Right - 5,800 Btu/h
#97 - Rear Right - 10,500 Btu/h
Main Orifices 5 Burner:
#97 - Front Left - 10,500 Btu/h
#89 - Rear Left - 8,500 Btu/h
#74 - Right Center - 5,800 Btu/h
#97 - Rear Center - 10,500 Btu/h
#89 - Rear Right - 8,500 Btu/h