Frequency Of Use; Ac Circuit Breakers; Power Management - Westinghouse WGen12000 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to
the Battery Maintenance and Storage sections of this
manual for information regarding battery charging and fuel
deterioration.

AC CIRCUIT BREAKERS

The circuit breakers will automatically switch OFF if there
is a short circuit or a significant overload of the generator
at each receptacle.
If an AC circuit breaker switches OFF automatically,
check that the appliance is working correctly and it does
not exceed the rated load capacity of the circuit before
resetting the AC circuit breaker ON.
The main circuit breaker controls total output of all outlets to
protect the generator from overload or short circuit.
Receptacle Circuit Breakers
ON
Push to Reset
OFF
GENERATOR CAPACITY
Do not overload the generator's capacity. Exceeding the
generator's wattage/amperage capacity can damage
the generator and/or electrical devices connected to it.
Make sure the generator can supply enough continuous
(running) and surge (starting) watts for the items you will
power at the same time.
The total power requirements (Volts x Amps = Watts) of all
appliances connected must be considered. Appliance and
power tool manufacturers usually list rating information
near the model or serial number.
To determine power requirements:
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This
is the amount of power the generator must produce
to keep the items running. See the wattage reference
chart on the next page.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
Main Circuit Breaker
NOTICE
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
RV Air Conditioner (11,000 BTU)
Operating
*Wattages listed are approximate. Verify actual wattage.

POWER MANAGEMENT

To prolong the life of the generator and attached devices,
Tripped
use care when adding electrical loads to the generator.
There should be nothing connected to the generator
outlets before starting the engine. The correct and safe
way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Westinghouse Outdoor Power Equipment, LLC | 17
Running
Tool or Appliance
Watts*
1010
TV (Tube Type)
RV Refrigerator
Radio
Light (75 Watts)
Coffee Maker
2590 Total
Running
Watts*
Total Running Watts
Highest Starting Watts
Total Starting Watts Needed
Starting
Watts*
1600
300
0
180
600
200
0
300
0
600
0
1600
Highest
Starting
Watts*
2590
+ 1600
4190

Publicidad

Tabla de contenido
loading

Tabla de contenido