11 Disassembly
DANGER
Risk of injury due to unexpected start
Improper operation can lead to serious injuries that could result in death.
The following instructions must be adhered to during all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Close off the gas supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
• Observe the information provided in the following chapter:
 8 Putting out of operation on page EN-18.
 Fig. 8 Attaching the CAT3 PRO CR to the robot on page EN-14
 Fig. 9 Attaching the CAT3 PRO TR to the robot on page EN-15
Disassembly takes place in reverse order.
Removing the CAT3 PRO CR torch mount
1)
1
1
Cylinder head screw
2
Cone clamping element
3
Outer ring
Fig. 12
1 Loosen the cylinder head screw (1). Remove the cone clamping element (2) and outer
ring (3).
2 Loosen the torch mount (4) from the CAT3 PRO CR adapter (5).
BAL.0843.0 • 2021-02-26
2
3
Removing the CAT3 PRO CR torch mount
2)
4
4
Torch mount
adapter
5
CAT3 PRO CR