4. NOMENCLATURE
4.1. DESCRIPTION OF THE INSTRUMENT
4.2.
PERCENTAGE CURRENT VALUES VISUALIZATION
The instrument allows the visualization of the DC current value measured in the range
from 0 to 20mA in percentage form on the upper part of the display. The followed
shows the relative correspondence
Table 1: Indication of correspondent percentage values
Fig. 1: Description of the instrument
Measured value
0mA
2mA
3.2mA
3.6mA
4mA
8mA
12mA
16mA
20mA
CAPTION:
1. Detachable clamp
2. Hand protection barrier
3.
4.
5.
6. HOLD key
7. ZERO key
8. LCD display
9. White LED illuminator
10. Battery cover fastening
11. Arrow for current
Percentage value
-25.0%
-12.5%
-5.0%
-2.5%
0.0%
25%
50%
75%
100%
EN - 5
(ON/OFF) key
key
key
screw
direction
HT8041
Table 1