Specifications
Current supply
Settling time per IEC 61298-2
Switch-on time
Ingress protection (IP code) per
IEC 60529
Pin assignment
Short-circuit resistance
Reverse polarity protection
Insulation voltage
Material (wetted)
Material (in contact with the
environment)
Pressure transmission medium
Vibration resistance per IEC
60068-2-6
WIKA operating instructions pressure transmitter, model A-10
Current (2-wire)
Voltage (3-wire)
Ratiometric (3-wire)
Measuring range ≥ 0.4 bar [≥ 5.8 psi]
Measuring range < 0.4 bar [< 5.8 psi]
Measuring range ≥ 0.4 bar [≥ 5.8 psi]
Measuring range < 0.4 bar [< 5.8 psi]
The stated ingress protection only applies when plugged in using mating connectors that have
the appropriate ingress protection.
Angular connector DIN 175301-803 A
Angular connector DIN 175301-803 C
Circular connector M12 x 1
Cable outlet
See product label
S+ vs. 0V
U
vs. 0V
B
No reverse polarity protection with ratiometric output signal
DC 500 V
< 10 bar [150 psi]
≥ 10 bar [150 psi]
≤ 25 bar abs. [400 psi]
Stainless steel 316L
■
HNBR
■
PA and PBT
■
< 10 bar [150 psi]
≥ 10 bar [150 psi]
≤ 25 bar abs. [400 psi]
10 g
■
1)
20 g (≥ -30 °C [-22 °F])
on request
2)
■
Signal current, max. 25 mA
8 mA
8 mA
< 1 ms
< 1 min
< 15 ms
< 1 min
IP65
IP65
IP67
IP67
Stainless steel 316L
Stainless steel 316L and PH grade steel
Stainless steel 316L
Synthetic oil
Synthetic oil
Dry measuring cell
EN