5. PROGRAMMATION
5.2 Programmation avancée
IL EST UTILISÉ POUR RÉGLER
LE COURANT MAXIMAL
DE SURCHARGE DU MOTEUR
RANGE 0.5 ÷ 18.0A (SA672.xx)
RANGE 0.5 ÷ 90.0A (SA675.xx)
COURANT MAXIMAL
MAN. 16.5 A
MAN. INDIQUE QUE
LA VALEUR DU COURANT
MAXIMAL A ÉTÉ DÉFINIE
MANUELLEMENT
COURANT MAXIMAL
AUT.
16.5 A
AUT. INDIQUE QUE LA VALEUR DU
COURANT MAXIMAL A ÉTÉ DÉFINIE
AVEC L'AUTO-APPRENTISSAGE
IL EST UTILISÉ POUR RÉGLER
LE DÉLAI D'INTERVENTION POUR LA
PROTECTION SUR LE COURANT
RANGE 1 ÷ 8s
DELAI COURANT
4 s
DELAI COURANT
4 s
OFF EXCLUT LE CONTRÔLE
SUR LE COURANT MINIMAL
COURANT MINIMAL
OFF
IL EST UTILISÉ POUR RÉGLER
LE COURANT MINIMAL
DU MOTEUR
RANGE 0.5 ÷ 15.0A (SA672.xx)
RANGE 0.5 ÷ 33.0A (SA675.xx)
COURANT MINIMAL
AUT.
9.9 A
MAN. INDIQUE QUE
LA VALEUR DU COURANT
MINIMAL A ÉTÉ DÉFINIE
MANUELLEMENT
COURANT MINIMAL
AUT.
9.9 A
AUT. INDIQUE QUE LA VALEUR DU
COURANT MINIMAL A ÉTÉ DÉFINIE
AVEC L'AUTO-APPRENTISSAGE
STABLE DÉMARRE LE MOTEUR AVEC
UN PULSE SUR LE BOUTON MAN;
ARRÊTE LE MOTEUR AVEC UN
PULSE SUR LE BOUTON RESET
BOUTON MANUEL
STABLE
INSTABLE DÉMARRE LE MOTEUR
SEULEMENT PENDANT LA
PRESSION SUR LE BOUTON MAN
BOUTON MANUEL
INSTABLE
BOUTON MANUEL
INSTABLE
10
IL SERT POUR DÉFINIR
LE TEMPS DE RÉARMEMENT
SUR LE COURANT MINIMAL
RANGE 1min ÷ 99h 59min
REARMEM. COURANT
MINIMAL 0 h 5 m
REARMEM. COURANT
MINIMAL OFF
OFF EXCLUT LE RÉARMEMENT
COURANT MINIMAL
REARMEM. COURANT
MINIMAL OFF
IL EST UTILISÉ POUR RÉGLER
L'ATTENTE PRÉSENCE RÉSEAU
RANGE 1 ÷ 30min
ATTENTE PRESENCE
RESEAU 1min.
ATTENTE PRESENCE
RESEAU OFF
OFF EXCLUT L'ATTENTE
PRÉSENCE RÉSEAU
ATTENTE PRESENCE
RESEAU OFF