Related board wiring of Power Optimizer connections can be made as shown below:
Cable Terminal
6 (CN20-2)
5 (CN20-1)
Current limit of the main power line, which can be defined by main power regulations or by the
limitations of power switches used, is set through the DIP switch located on the mainboard of the
EVC04 charging station.
According to the limit set by the user, charging station adjusts its output charging current dynamically
according to the measurement of main power line. When total current drawn by the charging station
and household appliances reach the limit set via the DIP switch, the amount of current allocated
for the charging station will be decreased.
8
7
6
5
4
3
2
1
Cable Color
White Blue
Blue
© 2021 Vestel - All rights reserved
8
7
6
5
4
Figure-6
Table-1
ON
ON
1
2
3
4
OFF
Figure-7
3
2
1
Description
A (COM)
B (COM)
5
6