Operating instructions and warnings
1-2
Free contact max. capacity 5 A : this contact can be used to control an open gate
warning light (P27=0) or a courtesy lamp (P27≠0)
LC/SCA
Electric lock output art. 110 12V
3-4
ELETTR
Flashing light output 24 V
5-6
not demand the use of a flashing light card)
LAMP
Motor 2 output 24 V
M2
7-8
Motor 1 output 24 V
M1
9-10
11
N.C. leaf nr. 1 safety device input. In case of activation it reverses the movement
SIC1
(P18=0) or it stops (P18=1). If unused, short circuit to the terminal n°16
12
N.C. leaf nr. 2 safety device input. In case of activation it reverses the movement
SIC2
(P18=0) or it stops (P18=1). If unused, short circuit to the terminal n°16
13
N.C. Photocell input. In case of activation it reverses the movement only while closing
FOTOC
(P26=0) or it reverses the movement while closing and stops while opening (P26=1).
If unused, short circuit to the terminal n°16
14
+24 V
+24VSIC
supply of photocell transmitters (in all cases) and of safety devices when testing these
latter before each operation
15
+24 V
+24VAUX
To be used as power supply of any auxiliary devices, photocell receivers (in all cases),
and of safety devices when not testing these latter before each operation
16
Common safety devices / Connection of motors metallic parts
COM
17
N.C. motor nr. 2 closing limit switch input. If unused, it may remain disconnected
FCC2
18
N.C. motor nr. 1 closing limit switch input. If unused, it may remain disconnected
FCC1
19
N.C. motor nr. 2 opening limit switch input. If unused, it may remain disconnected
FCA2
20
N.C. motor nr. 1 opening limit switch input. If unused, it may remain disconnected
FCA1
21
N.O. open input. If activated, it opens or closes both motors. It can work in "reversal"
START
mode (P25=0) or "step-by-step" mode (P25=1)
22
N.O. pedestrian opening input. If activated, it opens motor nr. 1 only.
PEDON
23
N.O. stop input. If activated, it stops the movement of both motors during any opera-
STOP
tion. If unused, short circuit to the terminal n°24
24
Common inputs
COM
Aerial signal input
25
26
Aerial ground input
27-28
24 V
24VBatt
16
29-30
24 V
24Vac
8 USE INSTRUCTIONS
After making all connections to the terminal board, remember to short-circuit, whenever needed, any
unused input (see "connection to the control board") and power the card: on the display you will read for
a few seconds "rES-" followed by the symbol "----" which stands for gate closed.
8.1 Visualisation of inputs status
Press on the "OK" key to check that all inputs have been properly connected.
Table 1 Terminal board connection
max 15W art. Lumy 24S (the intermittent output does
max 70W
max 70W
power supply output for controlled safety devices. To be used as power
power supply output for auxiliary circuits and uncontrolled safety devices.
battery power supply input (Follow carefully polarity indications)
transformer power supply input
15VA