019-4010 ROOF ANCHOR COMPONENTS
FIGURE 5 - ANCHOR COMPONENTS
A
B
C
D
019-4010 Temporary Roof Anchor Components
A
Pre-Drilled Fastener Holes
B
Steel Base Plate
C
Swivel Connection Point
D
Pre-Drilled Fastener Holes
INSPECTION
• SAFEWAZE™ Anchors shall be inspected prior to each use by the user and at least every 12 months
by a Competent Person. Annual inspections shall be documented. Severity of conditions during use
may necessitate increased frequency of documented inspections.
• Anchors that fail inspection MUST be removed from service.
• Prior to each use, inspect the 019-4010 Roof Anchor for deficiencies or damage, including, but not
limited to, sharp edges, rough edges, deformations, corrosion, pits, burrs, chemical exposure, extreme
heat exposure, or missing or illegible labels. If any deficiencies or defects are found, the 019-4010 must
IMMEDIATELY be removed from service.
• The 019-4010 Roof Anchor must be inspected at least every 12 months by a Competent Person other
than the user. Competent person inspections must be recorded in the inspection log included in this
manual and on the inspection grid label on the 019-4010.
• The eyelet on the 019-4010 should be straight and inline with the anchor and the fall of the roof. If the
eyelet is distorted or deformed, this will indicate that the 019-4010 has arrested a fall.
INSTALLATION
1. Under guidance of a Competent or Qualified Person, a suitable anchor point must be chosen that
meets the strength requirement, minimizes free fall, and reduces swing fall hazards. Do not work above
the anchorage point.
2. The 019-4010 Roof Anchor can be installed on any structure that meets the strength requirements as
defined in the SPECIFIC ANCHOR APPLICATIONS section of this manual for Personal Fall Arrest.
3. The 019-4010 Roof Anchor must be installed parallel with the roof sheets. The 019-4010 must be
installed on the roofing panel aligned with the fall of the roof and centered over a roof joist. The
019-4010 can be installed on a fininshed shingled roof with no need to remove shingles. (See Figure 6C)
4. Secure the 019-4010 Roof anchor to the roof by installing (6) 1/4" x 3" Steel Hex Head Lag Screws
through the holes in the 019-4010, penetrating through the sheathing and into the roof joist. Sheathing
must be a minimum of 1/2" thick and fasteners must be fully embedded. (See Figure 7)
5. The 019-4010 are not designed for rappelling or lifting operations.
6. The 019-4010 is not suitable for use with Horizontal Lifeline Systems.
7. The 019-4010 Roof Anchor can be removed and re-used unless the anchor is damaged or has
experienced Fall Arrest Forces. If either of these conditions exist, the anchor must IMMEDIATELY
removed from service and destroyed.
8. The 019-4010 is designed as a fall arrest anchorage for a single user with a maximum weight capacity
of 310 lbs. including tools and equipment.
9. The allowable working radius of the 019-4010 Roof Anchor is 360°. The 019-4010 is
Multi-Directional, and will arrest a fall from any direction relative to the anchor. (See Figure 8)
TYPICAL USAGE EXAMPLES
INSTALLATION EXAMPLE
FIGURE 6B - CUT AWAY VIEW
SHEATHING
INSTALLATION EXAMPLE
(6) 1/4" x 3"
Steel Hex
Head
Lag Screws
Sheathing
FIGURE 8 - ALLOWABLE WORK RADIUS
I
I
322 Industrial Court, Concord NC, 28025
Phone: 704-262-7893
FIGURE 6A - INSTALLATION
(6) 1/4" x 3"
Steel
Hex Head
Lag Screws
FIGURE 6C - CUT AWAY VIEW
SHINGLE
ROOF
TRUSS
TRUSS
FIGURE 7 - INSTALLATION
(6) 1/4" x 3"
Truss
Steel Hex Head Lag Screws
360°
I
I
Fax: 704-262-9051
Email: info@safewaze.com
WARNING
• Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event.
Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall
arrest forces. Women who are pregnant, individuals considered minors must not use any SAFEWAZE™
equipment.
• Never alter any part of a anchor or add/remove components. SAFEWAZE™ shall not be held
responsible for injury or death due to tampering.
• Anchors that are exposed to fall arrest forces MUST be IMMEDIATELY removed from service and
destroyed.
• Failure to follow these instructions and warnings could result in serious injury or death in the event
of a fall.
• A preplanned rescue procedure in the event of a fall is required. The rescue plan must be specific to
the project. The rescue plan must allow for employees to rescue themselves, or to be promptly rescued
by alternative means.
• Harnesses or connectors selected for use with any SAFEWAZE™ anchor must be compatible in size
and configuration. User must ensure compatibility of snap hooks, carabiners and other connectors. Any
connection which could allow disengagement must be eliminated. Snap hooks and carabiners must be
self locking and self closing and must never be hooked to each other.
• A Competent Person must conduct an analysis of the workplace and anticipate where workers will be
conducting their duties, the route they will take to reach their work, and the existing and potential fall
hazards they may be exposed to. The Competent Person must choose the fall protection equipment
to be utilized.
• Do not misuse equipment.
• Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or
equipment unless specifically certified for such use.
WARRANTY
SAFEWAZE™ warrants its products are free from defects in materials and construction under normal
use and service. Liability is not accepted for abuse, modification, improper use, destructive activity and
contaminated exposure.
MAINTENANCE & STORAGE
The 019-4010 Roof Anchor can be cleaned with water and mild soap if necessary. User should remove
all dirt, possible corrosives, and contaminants from the anchor prior to, and after each use. Never use
any type of corrosive substance to clean the 019-4010.
Excess water should be blown out with compressed air. Hardware can be wiped off with a clean, dry
cloth.
When not in use, store the 019-4010 Permanent Roof Anchor in a cool dry area where it will not be
exposed to extreme light, extreme heat, excessive moisture, or possibly corrosive chemicals or
materials.
LABELS
Part# 019-4010
360° Roof Anchor (Temporary)
Materials: Zinc Plated Steel
Capacity: 130-310 lbs including clothing, tools, etc.
OSHA 1926.502
Manufacture Date: April 2018
Serial #: XXXXXXX
Inspection Log
WARNING
THIS EQUIPMENT IS DESIGNED FOR USE AS A FALL
PROTECTION ANCHOR. USER MUST READ AND FOLLOW
DO NOT
INSTRUCTIONS SUPPLIED WITH THIS PRODUCT AT TIME OF SHIPMENT. FAILURE TO DO
REMOVE
SO MAY RESULT IN SERIOUS INJURY OR DEATH. AVOID CONTACT WITH HAZARDS INCLUDING,
BUT NOT LIMITED TO, HEAT, CHEMICALS, ELECTRICITY, AND SHARP OR ABRASIVE EDGES AND
LABEL
SURFACES. MAKE ONLY COMPATIBLE CONNECTIONS. REFER TO INSTRUCTIONS FOR
APPROPRIATE INSTALLATION AND CONNECTION METHODS.
INSTALLATION
Install the anchor in the roof field on top of sheathing directly over a
rafter of a wood roof structure. Support structure must be able to
support the loads the anchor will be subjected to in normal use. Drive in the supplied six 5/16"x3"
019766
lag bolts supplied with the anchor. See user instruction manual for complete installation
procedures and limitations.
INSPECTION
User must inspect the unit prior to each use. A Competent
Person must perform an inspection of this unit every 6 months.
If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE. Remove the anchor
from service IMMEDIATELY if it has been subjected to fall arrest forces. See the user
instruction manual for complete inspection procedures.
019767
INSPECTION LOG
Date
Inspection Items
Corrective Action
Noted
I
Web: safewaze.com
J
F
M
A
M
J
J
A
S
O
N
D
Initials