Installation To The Propane Gas Tank; Refilling The Propane Gas Tank - Dyna-Glo FA 60 Serie Manual Del Usuario E Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROPANE CONSTRUCTION HEATER
IMPORTANT:
You must use a propane/LP gas supply cylinder that is compatible with the connection device
provided with the hose and regulator.
1
2
3
4
C
D
E
Connector Inlet
Connector lnlet
FIGURE 1
Hose Fitting
Hose Fitting
F
REV NO.
REVISION DESCRIPTION
TOLERANCES UNLESS OTHERWISE SPECIFIED
MATERIAL SPEC.
FA60Q
±1.0mm
±.08mm<=
12.7mm
ECN NO.
±.03inch
±.003inch<=
0.50
C
FINISH:
±2°Angular
±.25mm>
12.7mm
CRITICAL DIMENSION
±.010inch>
0.50
SCALE:DO NOT SCALE
REV DATE
DESCRIPTION
BEND
0.3970mm
-0 +0.025 mm
1. Provide propane/LP supply system. Ensure that the valve on the cylinder is fully closed by turning the knob
RADIUS:
0.0156inch -0 +0.001 inch
1
2
3
4
fully clockwise (
2. Connect hose to heater inlet. (See Figure 1). Tighten firmly using a wrench. You must use the regulator
supplied with heater.
3. Connect fuel gas fitting hose/regulator assembly to propane LP tank(s).
(See figure 2) Turn POL Fuel fitting counterclockwise into threads on tank. Tighten
firmly using a wrench. Some models have a hand wheel that can be used to tighten the fitting. This hand
wheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT:
Position regulator so that hose leaving the regulator is in a horizontal position.
4. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTE: If not opened slowly, excess flow
device in regulator may stop gas flow. If this happens, close propane/LP supply valve, wait one minute
(or until you hear a click) and open again slowly.
5. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints.
Bubbles forming show a leak that must be corrected.
6. Close propane / LP supply valve before attempting to repair connection.
WARNING
has been thoroughly trained in accepted LP gas industry procedures. Failure to follow
these instructions may result in explosion, fire, severe personal injury, or death.
ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
• Turn heater gas valve knob and gas tank valve to OFF position.
• Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS. Turn POL fitting
CLOCKWISE to loosen. Protect POL fitting when disconnected from tank.
• Have tank filled by your local Propane gas supplier.
• Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTERCLOCKWISE.
• With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks
with soap solution.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!

INSTALLATION TO THE PROPANE GAS TANK

5
6
7
8
9
C
D
E
Hose to Regulator
Hose to Regulator
APPROVED FOR PRODUCTION
ECN#
APPROVED
DATE
F
DRAFTER
DATE:
FIRST ANGLE
Gavin TT
PROJECTION
2019-4-3
Yeah
GHP GROUP INC
FRONT
RIGHT SIDE
VERIFIED
DATE:
SHEETS:
1 of 1
APPROVED
DATE:
MODEL NUMBER:
5
6
7
8
9
). Ensure that the cylinder is fully upright for vapor withdrawl. (see size/capacity, page 7).
: Purging and filling of LP gas tanks must be performed by personnel who

REFILLING THE PROPANE GAS TANK

Regulator
Propane/LP
Supply Valve
Propane/LP
Tank
FIGURE 2
9
Hose to Heater
POL Fuel Gas
Fitting

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Fa 125 serie