Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
The R12V is a battery operated back-up sump pump. It
does not replace a regular pump. It is designed to provide
protection in the event household electrical power fails.
Unpacking
Inspect this unit before it is used. Occasionally, products
are damaged during shipment. If the pump or components
are damaged, return the unit to the place of purchase for
replacement. Failure to do so could result in serious injury or
death.
Safety Guidelines
This manual contains information that is very important
to know and understand. This information is provided for
SAFETY and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information, observe the following
symbols.
Danger indicates an imminently
hazardous situation which, if NOT
avoided, WILL result in death or serious injury.
Warning indicates a potentially
hazardous situation which, if NOT
avoided, COULD result in death or serious injury.
Caution indicates a potentially
hazardous situation which, if NOT
avoided, MAY result in minor or moderate injury.
Notice indicates important
information, that if NOT followed, MAY
cause damage to equipment.
General Safety Information
Do NOT use to pump
fl ammable or explosive fl uids
such as gasoline, fuel oil, kerosene, etc. Do NOT
use in a fl ammable and/or explosive atmosphere.
pump SHOULD only be used to pump clear water.
Fatal injury and/or property damage COULD result.
If the basement has
water or moisture on the
fl oor, do NOT walk on wet area until all power is
turned off. If the shutoff box is in the basement,
call an electrician. Remove pump and either repair
or replace. Failure to follow this warning COULD
result in fatal electric shock.
All wiring must be performed by a
qualifi ed electrician.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2017, Ridge Tool Company.
12-Volt Backup
Sump Pump
explosion or fi re COULD result.
protection MUST be worn when handling the battery.
designed to handle efl uent, salt water, brine, laundry discharge,
or any other application which may cause caustic chemicals and/
or foreign materials. Pump damage MAY occur if used in these
applications and WILL void the warranty.
Battery Information
The system is designed to operate most efficiently with sealed
lead acid (SLA) batteries. Sealed lead acid batteries cost
slightly more, but they can last longer. The oversize battery
case (included) will accommodate a 12-volt SLA battery (up to
a 27-frame size).
Be certain that the area around the batteries is well ventilated.
Before servicing the batteries, blow away gasses by waving a
piece of cardboard near the batteries.
charging. Sparks CAN ignite the gas in an enclosed space. Wear
safetly goggles when connecting batteries. Battery connections
SHOULD be made in a well ventilated area.
making the connections or servicing the batteries, read and
follow instructions on all applicable instruction manuals. To
reduce the risk of battery explosion, follow the instructions in
this manual and those published by the battery manufacturer,
as well as those of any other equipment used in the surrounding
area.
An assistant should be present or close enough to come to
your aid in the event of an emergency. Have a reliable source
of fresh water and soap nearby in case batttery acid contacts
skin or eyes.
Do NOT expose battery to
sparks or fl ame as an
Battery acid is corrosive
Avoid spilling on skin or clothing. Eye
A check valve MUST be used on the
primary sump pump discharge.
A ground fault circuit interrupter
(GFCI) is required.
This pump MUST only be used to pump
clear water only. This pump is not
Dangerous hydrogen gas CAN
be released from the batteries while
Working in the vicinity of lead acid
batteries CAN be dangerous. Before
3522 00-005
R12V
8/17

Publicidad

Tabla de contenido
loading

Resumen de contenidos para RIDGID R12V

  • Página 1 Description Do NOT expose battery to sparks or fl ame as an The R12V is a battery operated back-up sump pump. It explosion or fi re COULD result. does not replace a regular pump. It is designed to provide protection in the event household electrical power fails.
  • Página 2: Product Warranty

    NEVER smoke or allow a spark or fl ame in the vicinity of the battery. Avoid dropping metal tools on the Thank you for making RIDGID a key part of your home battery posts because they MAY spark or maintenance program. If properly installed, maintained and short-circuit the system or battery, causing an explosion.
  • Página 3: Pump Installation

    R12V Pump Installation 5. Place the pump with the 4 ft. section of PVC pipe on a solid, level surface in the sump pit on an elevated The back-up pump can be installed with a separate dedicated surface. discharge line (Method 1), or tied into an existing sump pump line 6.
  • Página 4: Control Box Installation

    Operating Instructions and Parts Manual Method 2 If a separate, dedicated discharge is not possible as in Method 1, the back-up pump can be tied into the AC operated pump's discharge pipe by installing a "Y" connector. Two check valves will be required. 1.
  • Página 5 R12V 4. Test pump operation by filling the sump with water d. Plug in transformer and main AC pump. while the main pump is unplugged. If the pump When main AC power is out, and when pump has been operates properly, plug the transformer into the GFCI running, the lights will indicate battery status.
  • Página 6: Troubleshooting Chart

    Operating Instructions and Parts Manual Batteries If battery acid contacts your eye(s), fl ush with cold running water for 10 minutes Dangerous hydrogen gas CAN be and seek immediate medical attention. If acid contacts your released from batteries while charging. eyes, skin or clothing, wash immediately with soap and water.
  • Página 7 R12V For Replacement Parts or Technical Assistance, Call 1-877-9RIDGID Please provide following information: Address any correspondence to: - Model number RIDGID PUMPS - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Página 8 RIDGID water pumps are warranted to be free of material and workmanship defects for the two-year period from the date of purchase. This warranty is specific to this water pump and for the original owner and may not be transferred.
  • Página 9: Descripción

    No exponga la batería al contacto de chispas o llamas ya que podría La R12V es una bomba auxiliar para sumideros que funciona provocar una explosión o un incendio. L’acide de pile est con batería. No reemplaza a una bomba regular. Está...
  • Página 10: Instalación De La Bomba

    El resto de la instalación de la tubería de descarga variará dependiendo de las circunstancias individuales. Dirija la La R12V puede instalarse como un sistema de respaldo tubería de descarga hacia una pared exterior, por el camino con una línea de descarga dedicada separada (Método 1), más corto, siguiendo las técnicas de instalación sanitaria más...
  • Página 11: Instalación De La Caja De Control

    Método 2 Si no es posible lograr una descarga separada y dedicada Viga del piso como en el Método 1, la bomba R12V puede conectarse a la tubería de descarga de la bomba que funciona con CA, Conector“Y” instalando un conector "Y". Se requerirán dos válvulas de retención.
  • Página 12: Funcionamiento

    Manual de Instrucciones de Operación y Piezas Verde: Indica que la batería está totalmente cargada. 4. Verifique el funcionamiento de la bomba llenando el Amarilla: Indica que la batería está parcialmente cargada, sumidero con agua y manteniendo desconectada la pero aún se puede operar. bomba primaria.
  • Página 13 R12V Trabajar en las inmediaciones de baterías 4. Desconecte la bomba principal y llene el sumidero de plomo-ácido puede ser peligroso. Antes de con agua hasta que se prenda la bomba auxiliar. Repita hacer conexiones o reparar las baterías, lea y siga las instrucciones en el procedimiento dos veces para asegurarse de que la todos los manuales de instrucciones aplicables.
  • Página 14: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción Correctiva La bomba no funciona 1. Conexiones flojas 1. Revise todas las conexiones 2. Batería baja o defectuosa 2. Revise la batería y reemplácela si está baja o defectuosa 3.
  • Página 15 R12V Para Ordenar Repuestos, Sírvase llamer al Concesionario más Cercano a su Domicilio 1-877-9RIDGID Dirección para correspondencia sobre repuestos: Sírvase proporcionar la siguiente información: RIDGID PUMPS -Número del modelo 101 Production Drive -Número de serie (de haberlo) Harrison, OH 45030 U.S.A.
  • Página 16 Para obtener servicio para esta bomba de agua RIDGID debe enviarlo, con el flete pagado, a un centro de servicio autorizado para la reparación de bombas de agua RIDGID. Puede obtener la ubicación del centro de servicio más próximo llamando...

Tabla de contenido