► Before reaching a critical temperature, the
temperature monitor switches off the dust
extractor.
► Switch off the dust extractor, allow to cool
for about 5 minutes, then switch on again.
Not possible to switch on: Contact Festool
customer service workshop.
8.4

The antistatic system

Friction inside the extraction hose causes static
electricity to develop during extraction. Operat­
ing personnel may receive unpleasant electric
shocks while working. The mobile dust extrac­
tor is fitted with an antistatic system as stand­
ard to discharge any static electricity that may
develop. However, always use the enclosed an­
tistatic extraction hose.
9
Working with the dust
extractor
WARNING
Not suitable to vacuum hazardous or toxic
substances or dusts e.g. asbestos.
► The filters will not be able to capture all
particles and may exhaust them back into
the environment.
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter bag!
Two cleaning nozzles are stored in the in­
side of the dust extractor [5-1].
Risk of tilting, do not place on sloped areas!
Observe the following instructions:
Risk of explosion and fire: Do not absorb:
– Sparks or hot dust;
– Combustible or explosive materials (e.g.
magnesium, aluminium, petrol, diluting
agents);
– Aggressive materials (e.g. acid, alkaline
solutions, solvents);
– Chemically reactive materials, which
lead to the generation of heat, acids/
bases, gases, etc. (e.g. reactive 2-compo­
nent materials, aluminium and water).
Observe all national safety regulations as
well as the material manufacturer's speci­
fications!
5
5-1
Do not lift or transport using a crane hook
or lifting gear!
Always use suitable protective equipment!
If intact following a visual inspection, work
in a dry environment according to instruc­
tions!
The dust extractor is a stationary system
and not suitable for pulling at the cable and
hose. Use handle [1-4].
Static charge may occur if an anti-static
suction hose is not used. The user may suf­
fer an electric shock.
Please note the following after the work:
► Switch off the dust extractor and pull out
the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
► Place suction hose [1-3] and mains power
cable in storage box.
► Clean inside and outside of dust extractor
by applying vacuum and wipe.
► Place the dust extractor in a dry room inac­
cessible to unauthorised users.