Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN

4 / INSTALLATION

Before connecting the appliance to the power supply, check that the
wires of your electric installation have sufficient diameter to supply
power to the appliance normally. The fuse for the installation
shouldbe 10 amps.
It is necessary to provide a bipolar cut-off device in the power supply
circuit, where the opening of the contacts is more than 3 mm.
The electric connection should be done before the appliance is set in the
cabinet.
The drawer should be connected by a (standard) power cord with three 1
mm² couplers (1 single phase + 1 N + ground) to the 220-240 V single
phase power supply via an electric circuit corresponding to the standard
CEI 60083 or complying with the installation rules. The protective wire
(green/yellow) corresponds to ground
on the appliance and should
be connected to the ground of the installation.
In the case of a connection via an electric outlet, the outlet should be
accessible after the installation of the appliance.
The neutral on the heating drawer (blue wire) should be connected to
neutral on the power supply.
WARNING : If the warming drawer malfunctions in any way, unplug
the appliance or remove the fuse corresponding to the sector where
the warming drawer is hooked up.
18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dwd1529

Tabla de contenido