Broan-NuTone RANGEMASTER RM53000 Serie Manual Del Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREPARE THE HOOD
(NON-DUCTED HOODS ONLY)
Note: The following materials must be purchased separately for non-ducted recircu-
lation installations.
Non - Ducted Recirculation Kit, Model RRK51.
5" diameter expandable / flexible aluminum duct.
1/16" diameter twist drill.
CAUTION: Do not use plastic or rigid metal ducting.
1. Determine the length of the compressed flexible aluminum ducting using the
following formula:
34" MINUS
Distance above
cook top. See Page
9, height restrictions
table.
Worksheet: 34" - __________ + ___________ (for 9' or 10' ceiling only) = __________
2. Discard the discharge collar/damper
supplied with the hood. Install the 5" to
6" adapter supplied with the Non-Ducted
Recirculation Kit.
3. Attach aluminum flexible duct to the 5"
adapter. Securely tape all joints with
duct tape to prevent separation of com-
ponents as flex ducting is expanded.
4. Assemble the recirculation plenum to
the flexible duct.
5. Drill three (3) 1/16" diameter equally
spaced holes through the duct and duct
connector of the recirculation plenum.
6. Secure duct to the plenum's connector
with (3) sheet metal screws: (3.9 x9.5
mm) Tape all joints with duct tape.
7. Secure electrical system plate to the
range hood with (2) mounting screws.
PLUS 12" If ceiling
height is 9-
feet. (or 24" If
ceiling height
is 10 feet)
PLENUM
3 SCREWS
5" ALUMINUM
FLEX DUCT
5" to 6"
ADAPTER
BLOWER
COLLAR
3.9 x 9.5mm
SCREWS
- 11 -
= Length of compressed
flexible aluminum
ductwork.
ELECTRICAL
SYSTEM
PLATE

Publicidad

Tabla de contenido
loading

Tabla de contenido