The connection pipe should be insulated with proper water-proof insulating material.
The pipe wall thickness shall be 0.5-1.0mm and the pipe wall shall be able to withstand the
pressure of 6.0 MPa. The longer the connecting pipe, the lower the cooling and heating effect
performs.

4.4 Electrical Requirement

Electric Wire Size and Fuse Capacity.
Indoor Units
12~24k
220-240V~ 50Hz
Notes:
The fuse is located on the main board.
① .
Install the disconnect device with a contact gap of at least 3mm in all poles nearby the units
② .
(Both indoor unit and outdoor unit).The appliance must be positioned so that the plug is
accessible.
③ .
based on the maximum power (maximum amps) of the unit.
④ .
guarded multi-wire copper cable (like, YJV copper cable, consisting of PE insulated wires and
a PVC cable jacket) used at 40°С and resistible to 90°С(see IEC 60364-5-52). If the working
Size of Fitting
Pipe(Inch)
Liquid
1/4
3/8
Power Supply
Fuse Capacity
V/Ph/Hz
Table 3
Max.
Max. Height
Difference between
Pipe
Length
Indoor Unit and
Gas
(m)
Outdoor Unit (m)
3/8
20
1/2
20
5/8
30
Table 4
Min. Power Supply Cord
A
mm
5
0.75
13
Drainage
pipe(Outer
Diameter × wall
thickness) (mm)
15
15
Φ25×1.5
15
2