① . The power source capacity must be the sum of the air conditioner current and the current of other
capacity.
② .
raise the voltage.
5.6.2 Electrical Wiring
(1). For solid core wiring (Fig.36)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 25
mm (15/16") .
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
4). Shape the loop wire properly, place it on the terminal board and tighten securely with the
terminal screw using a screwdriver.
(2). For strand wiring (Fig.36)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 10
mm (3/8") .
2). Using a screwdriver, remove the terminal screw (s) on the terminal board.
3). Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped
wire end.
4). Position the round terminal wire, and replace and tighten the terminal screw with a
screwdriver.(Fig.37)
DC Inverter Free match Series Cassette Type Unit
Fig.37
CAUTION!
Fig.36
28
Fig.38