3.2 DIL switch setting
The settings of the DIL switches for configuring the pneu
matics (number of valve solenoid coils used) can be made
on the fitted CPX terminal.
1. Remove the screws and lift up the cover.
2. Set the DIL switches in accordance with the valve con
figuration (see following table).
3. Check the seal and sealing surfaces and refit the cover.
4. Tighten the screws by hand in diagonally opposite
sequence:
S CPX−GP−03−4.0: Tightening torque 1.0...1.3 Nm.
S CPX−GP−CPA−..: Place the screws so that the self−
S VABA−10S6−x1: Tightening torque 1,2 ... 1,8 Nm.
Festo CPX−GP−..., VABA−... 0503a English
cutting threads are used.
Tightening torque 0.9...1.1 Nm.
19