4. Maintenance
• Regular maintenance, electrical control system with high pressure air blow off the dust.
• Clean the tank at least once a week
Trouble clearing
No.
Problems
1
No ultrasonic
activity
2
Not well
cleaning
3
Electric Leakage A. Customer side not grounded
4
Other problems
Possible Cause
A. Power supply not connected
B. Fuse broken
C. Cable is short circuited
D. Transducer is short circuited
E. PCB Board broken
F. Other reasons
A. Not strong ultrasonic
cleaning
B. Too high or too low liquid
surface
C. Too high too low
temperature
D. Not suitable cleaning liquid
E. Other Reasons
B. Machine not grounded
Solutions
A. Check and plug power switch
B. Check the fitted power supply and change
the same specification fuse
C. Connect fitted cable or replace a new
D. Consult with your supplier
E. Check the broken part and change it
F. Consult with your supplier
A. Connect ultrasonic button and adjust
B. Adjust liquid into the best surface
C. Adjust the temperature into the most fitted
D. Stop and switch off power supply, replace
suitable liquid after previous liquid
cooling down
E. Consult with your supplier
A. Ensure it is grounded
B. Check if machine earth wire loosens
Consult with your supplier