INSTALLING THE UNIT

1. Carefully unpack your IRIS vacuum mixer,
and check for these fittings in the packaging:
Power cable.
Spare filter.
550 cc. mixing bowl (D).
Kit to secure the mixer to the wall.
Plastic
spatula
(R-060002).
2. Choose a wall well away from any sources
of heat, vibrations or moisture to set up the
mixer unit. It must also be positioned on a
firm, rigid, level surface.
3. Make two marks with a marker pen exactly
80 mm. apart at the chosen location. Ensure
that the imaginary line linking the two marks
is perfectly horizontal. A level may be used if
required.
4. Drill out the holes marked by hand using a Ø
6 mm widia bur.
5. Insert the nylon studs included in the
vacuum mixer kit in the drill holes. Then
screw in the cheese-head shed bolts,
allowing the heads to protrude around 12
mm.
6. Use the bolts to secure the IRIS vacuum
mixer firmly to the wall.
7. Use the pen to mark the position of the fixing
eye on the lower section of the unit. Remove
the mixer and drill out the hole manually.
Insert a nylon stud in the orifice and put the
unit back on.
8. Use a wrench to put the bolt through the
lower hole. Ensure the unit has been firmly
secured.
9. Hook up the mixer's power cable to 230 V,
50/60 Hz with earthing.
6
Distribuidor: DepoDent España
The
machine
has
for
plaster-alginate
depósito dental DepoDent España - 902 767 118 -
GB

OPERATING THE MIXER

The mixer is now ready for use:
been
1. Use the main switch (E) to turn on the
machine.
2. The upper display will show the spin speed
in rpm and the lower display will show the
working time in seconds.
3. You can change both of them by pressing
the
/
4. To shift from a display to the other press the
key.
5. Put the mixing ingredients into the bowl (D).
Pre-mix
manually with a spatula.
6. Use gentle pressure to position the bowl and
the mixer connection (F) with a good
sealing.
12. Press the START/STOP
unit to start a cicle.
13. Use the vacuum meter (B) to check the
vacuum in the bowl. If there is no vacuum in
the bowl, move it gently to improve its
seating. Keep hold of the bowl until the
meter needle moves and the cup keeps
holded. You may now release the bowl.
14. During mixing operations, the needle must
remain in the "VACUUM" section. When the
pre-set time has elapsed, the unit will stop.
15. Use the vacuum drain valve (C) to remove
the bowl from the unit. The mix is now ready
to be used.
16. To stop the operation of the unit at any
moment keep the START/STOP
pressed.
This machine has a "diaphragm" vacuum pump
(maintenance-free). If the unit is started at very
low room temperature, the membrane rubber
may not be sufficiently elastic for best operation.
Thus we recommend that the mixer be run for
approximately
operations in cold environments.
keys.
the
products
in
key again for the
IMPORTANT
1
minute
before
the
bowl
key
starting