RFDSC-11, RFDSC-71
Dimming socket
EN
Enchufe regulable
ES

Technical parameters /

Especifi caciones técnicas
Supply voltage:
Apparent power:
Dissipated power:
Supply voltage tolerance:
Dimming load:
Output
Contactless:
Load capacity:
Control
RF command from the transmitter:
Range in open space:
Manual control:
Other data
Operating temperature:
Storage temperature:
Working position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Dimensions:
Weight:
Related standards:
* capacity for power factor cos φ=1
The power factor of dimmable LEDs and ESL bulbs ranges from cos φ = 0.95 up to 0.4
An approximate value of maximum load may be obtained by multiplying the load capacity of the
dimmer by the power factor of the connected light source.
Attention:
The minimum distance between the controller (system unit) and the actuator must not be less
than one centimeter.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
ELKO EP ESPAÑA, S.L. | C/ Josep Martinez 15a, bj | 07007 Palma de Mallorca | e-mail: info@elkoep.es | Tel.: +34 971 751 425 | Fax: +34 971 428 076
Tensión de alimentación:
Consumo aparente:
Consumo de perdida:
Tolerancia de alimentación:
Carga regulable:
Salida
Sin contacto:
Carga de regulación:
Control
Orden RF desde controlador:
Rango al aire libre:
Control manual:
Más información
Temperatura de funcionamiento:
Temperatura de almacenamiento:
Posición de funcionamiento:
Montaje:
Protección:
Categoría de sobretensión:
Grado de contaminación:
Dimensiones:
Peso:
Normas conexas:
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
www.elkoep.com / www.elkoep.es
R
L
C
230 - 250V / 50-60Hz
1.1 VA
0.8 W
+10/ -15 %
R, L, C, LED, ESL
2 x MOSFET
300 W *
868 MHz, 915 MHz, 916 MHz
up to / hasta 160 m
button / botón PROG (ON/OFF)
-20 ... + 35 °C
-30 ... +70°C
any / cualquiera
plug into a socket / en toma de unchufe
IP30
III.
2
60 x 120 x 80 mm
129 g
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC) /
EN 60669, EN 300 220, EN 301 489 directiva RTTE, NVč.426/2000Sb (directiva 1999/ES)
* capacidad de factor de potencia cos φ=1
Factor de potencia de LED y ESL bombillas regulables su rango habitual es entre: cos φ = 0.95 hasta 0.4.
El valor aproximado se calcula multiplicando la capacidad de carga máxima de regulador y factor
de potencia de bombilla conectada.
Advertencia:
La distancia mínima entre el controlador (unidad de sistema) y la unidad no debe ser inferior a 1 cm.
Entre los diferentes ordenes debe pasar al menos 1s.
Advertencia
El manual de uso está dirigido para la instalación y el usuario del dispositivo. Manual siempre está incluido en
embalaje. La instalación y conexión puede realizar sólo personal con adecuadas cualifi caciones profesionales, de
conformidad con todas las regulaciones aplicadas, y que está perfectamente familiarizado con estas instrucciones
y funciones del dispositivo. Función del dispositivo también depende del transporte, almacenamiento y la manipu-
lación. Si se observa cualquier signo de daño, deformación, mal funcionamiento o pieza que falta, no instale este
producto y devolvelo al vendedor. Con el producto y sus componentes debe ser tratado después de su vida útil
como con residuos electrónicos. Antes de iniciar la instalación, asegúrese de que todos los cables, partes o termi-
nales conectados están sin la conexión a la red. En el montaje y el mantenimiento se deben observar las normas de
seguridad, normas, directivas y reglamentos para trabajar con equipos eléctricos. No toque las partes del dispositivo
que están conectadas en la red - puede producir peligro de vida. Debido a la transmisibilidad de la señal RF, observe
la correcta ubicación de los componentes RF en un edifi cio donde la instalación se lleva a cabo. RF Control está
diseñado para montaje en interiores, las unidades no están diseñados para la instalación en exteriores y espacios
húmedos, no se pueden instalar en cuadros eléctricos de metal y en cuadros eléctricos plásticos con puerta de
metal - lo que empeora transmisividad de la señal RF. RF Control no se recomienda para el control de dispositivos
que ofrecen funciones vitales o para controlar dispositivos tales como bombas, el. calentadores sin termostato,
ascensores, montacargas, etc. - Señal de radiofrecuencia puede estar bloqueado por una obstrucción, interferida,
la batería del controlador puede estar ya sin energía, etc. y por lo tanto el control remoto puede ser incapacitado.
ESL
LED
120 V AC / 60Hz
150 W*
02-44/2015 Rev.1