Checking For Leaks; Lighting Instructions; Shut Down Instructions - Protemp PT-18-PCH-A Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Checking For Leaks:

– To check for leaks, make up a 50/50 solution
of dish soap and water. Apply this solution to
all gas connections. If bubbles appear, there
is a leak. If a leak is found, turn off the gas
supply, and re-connect the leaking connection.
If the leak persists after several tries, contact
Pinnacle Customer Service at (800) 641-
6996.
– The installation of this heater must meet all
local codes and/or gas utility requirements. In
the absence of local codes, the National Fuel
Code ANSI Z223.1 should be followed.
– The minimum clearances to any combustible
construction materials must be maintained at
all times (See Page 3).
– Inspect the heater before each use, and at
least annually by a qualified service person.
Supply Valve
Regulator
Hose
Figure 6
WARNING
components while in operation. Keep gasoline
and any other flammable liquids away from the
heater.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO
®
OPERATION (CONT.)
Propane Tank
EXTREMELY HOT
during operation. Do
Not touch any metal
A FUEL SOURCE

Lighting Instructions:

1. STOP! Read all of the safety information
provided with this heater.
2. Turn valve on propane cylinder
COUNTERCLOCKWISE until fully open.
3. Wait five (5) minutes for any gas to clear. Smell
for gas. If none is evident, proceed to the next
step.
4. Push in the valve knob and turn to "PILOT".
NOTE: If this is first time use for heater or LP
cylinder has been replaced, hold the valve knob for
approximately 30 seconds to allow bleeding of air
from system then turn valve knob to PILOT.
5. While depressing the valve knob, press red piezo
ignition button to ignite. It may be necessary to
press the igniter button several times to ignite
the center burner panel.
6. Continue to hold valve knob down for 30
seconds after the panel has lit. This will heat
the thermocouple. After 30 seconds, release the
valve knob.
7. If heater fails to light, or does not stay lit, repeat
steps 2 through 6.
8. When the center burner panel stays lit, turn the
valve knob to the desired setting.

Shut Down Instructions:

1. Turn valve knob to the OFF position.
2. Turn the knob at the LP cylinder CLOCKWISE to
the OFF position.
3. Disconnect regulator hose assembly from the LP
cylinder.
8