7
SECOND FUNCTIONS MENU
Remote panel Item No 438 also has a second functions menu.
To turn on the second functions menu, press AN and AW simultaneously.
Turn AN to select a parameter. Turn AW to change the value.
Entry
Description
For TIG process only
TRG
Start pushbutton management mode
(2T, 4T, 3L, 4L)
SP
Spot (OFF, ON)
tSP
Weld spot duration
tIn
Spot intermittent function time
IGN
Arc strike type (HF, LIFT, EVO)
PrF
Pre-flow time
PoF
Post-flow time
IL1
First current level amplitude
tL1
First current level duration
tS1
First current ramp duration
tL2
Main current duration
IL4
4L central current
tL4
4L central current duration
tS2
Current final ramp duration
IL3
Amplitude of crater filling current
tL3
Crater filling current duration
PU
Pulse enablement (OFF, ON)
├─
PUF
Pulse frequency
├─
PUD
Pulse working cycle
├─
PUC
Pulse current
ACH
Hot Start in AC
PEN
Penetration half-wave form (sqr, sin,
tri)
CLN
Cleaning half-wave form (sqr, sin, tri)
ACF
AC waveform frequency
ACB
AC waveform horizontal balancing
ACA
Cleaning
adjustment
AMd
Working cycle in AC throughout total
MIX period
EST
EVO START adjustment
APC
APC process sensitivity adjustment
22/24
half-wave
amplitude
Min
Def�
2T
2T
OFF
OFF
0.01
1.00
OFF
OFF
HF
HF
0.1
0.1
0.1
10.0
0.1
25.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
50.0
0.0
0.0
0.0
0.0
0.1
10.0
0.0
0.0
OFF
OFF
0.1
1.0
10
50.0
0.1
50.0
0.1
1.6
sqr
sqr
sqr
sqr
90.0
-10
0
-80
0
10
50
OFF
OFF
1
20
Max
Unit
4L
-
ON
-
25.00
s
5.0
s
EVO
-
10.0
s
50.0
s
100.0
%
30.0
s
10.0
s
30.0
s
100.0
%
10.0
s
10.0
s
100.0
%
10.0
s
ON
-
2500.0
Hz
90.0
%
100.0
%
6.0
mm
-
-
200.0
Hz
10
-
80
%
80
%
1.0
s
80
A/V
Res�
-
-
0.01
0.1
-
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
-
0.1
0.1
0.1
0.1
-
-
0.1
0.1
1
1
0.1
1