Installation and Use
Guardian Fall Protection Halo Series SRLs MUST NEVER be used in Leading Edge (LE) applications.
No free fall is allowed.
ALWAYS avoid lifeline contact with sharp or abrasive edges and surfaces.
1. All components of the personal fall arrest system must be selected and deemed compatible with applicable
SRL by a Competent Person.
2. Ensure structure to which SRL is to be attached, and on which work is to be performed, is free of all hazards,
including, but not limited to, debris, rot, rust, sharp or abrasive edges and surfaces, and hazardous materials.
3. Halo Big Block SRL may be used in stationary applications only; attach Halo Big Block SRL carabiner to
selected anchorage connector, and attach snap hook to applicable harness D-ring.
4. Ensure 100% tie-off will be maintained at all times, which may require the use of a back-up or
supplementary fall protection system.
Maintenance, Cleaning, and Storage
Repairs to Halo Series SRL can only be made by a Guardian Fall Protection representative or an entity
authorized by Guardian. Contact Guardian for all maintenance and repair needs at: 1-800-466-6385. If Halo
Series SRL fails inspection in any way, immediately remove it from service, and contact Guardian to inquire
about its return or repair.
Cleaning after use is important for maintaining the safety and longevity of Halo Series SRL. Remove all dirt,
corrosives, and contaminants from Halo Series SRL before and after each use. If Halo Series SRL cannot be
cleaned with plain water, use mild soap and water, then rinse and wipe dry. NEVER clean Halo Series SRL
with corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.