xChargeIn
4
Displays and operating elements
4.1
LED bar
Fig. 4-5: Segments of the LED bar
The LED bar provides visual information about the current operating status
of the charging station. It consists of 4 segments
up or flash, together or individually, in various colors.
The LED bar is only visible with activated power supply.
Dark
Flashing green
(every 3 seconds)
Flashing blue
(every 3 seconds)
Flashing green
(after plugging in)
Green
Flashing green
(every second)
Flashing green
(every 3 seconds)
Flashing orange
(every 5 seconds)
Blue and orange
Orange
(5 seconds)
Orange
(S2)
Flashing red
Blue/red
Red/white
Operating instructions V1.04
© EATON
Display
No power supply or defect, for details see "Diagnosis"
Ready for operation
or with authorization option: Authorization done correctly
The charging station is waiting for authorization to enable a
charging process.
Locking of the charging cable to the charging socket
The plugged-in charging cable is locked and charging can be
started by the vehicle.
Execution of a charging process (applies to "EN 61851 Mode 3"
charging process)
Charging complete and charging socket unlocked. The charging
cable can be unplugged.
If the charging station is out of service, for example in the event
that the temperature is exceeded, the charging process is tem-
porarily interrupted and resumed after cooling down.
The charging station is in start-up.
Self-test during start-up
The charging station is in commissioning mode.
Error, for details see "Diagnosis"
Error display via color code, for details on possible causes of er-
ror and troubleshooting see "FAQs" on our website
Displays and operating elements
(S1
to S4), which can light
Description
111