4.

Technical Specifications

Product group:
EMC:
Electrical safety:
Protection degree
Protection class:
Test voltage:
Dimensions W × H × D
Ambient temperature:
Cooling:
Humidity:
Storage temp.:
Long-term storage:
Input
Input AC:
Input DC:
Rated current:
Overvoltage protection:
Connections:
Output
Output DC (SELV):
Rated current:
Ripple:
Efficiency:
Current limitation:
Connections:
Digital connections
Connection facilities:
Connections:
Primary switched-mode voltage regulator (single
phase, primary switched built-in power supply with
Ethernet-CAN coupler)
EN 61000-6-3 (unwanted emission)
EN 61000-6-2 (interference immunity)
EN 60950
IP 20
I
4.2 kV DC
80 × 165 × 145 mm
-10 to +70 °C / from +55 °C -3 %/K
Natural convection
30 to 80 % relative humidity
There must be no dew formation when the system is
to be commissioned.
-25 to +80 °C
To maintain the condensers, apply mains voltage to
the device for at least 5 min. every two years.
Rated voltage 100 – 250 V AC / 50 – 60 Hz
Range 90 – 264 V
Rated voltage 140 – 300 V DC
Range 130 – 300 V
additional external fuse protection is required
0.6 A at 230 V AC
Varistor in the input circuit
WAGO series 231 multiplug-system for max. 2.5 mm²
Rated voltage 24 V DC
Range 22 – 28.8 V (preset to 24 V)
2,5 A at 24 V DC
150 mVpp (at 20 MHz)
89 %
from 1.1 × I
rating
WAGO series 734 multiplug-system
for max. 1.5 mm²
Ethernet, SD-Card, UPS
WAGO series 734 multiplug-system for max. 1.5 mm²