5.

Special Features

• Wall mounting or installation on top-hat rail TS 35 in compliance with EN 50022
• Long-range input for DC and AC current
• Maintenance free
• Open-circuit proof
• Short-circuit proof
• Protected both on the inside as well as the outside by an internal fuse
• Protected on the outside by an electronic voltage/current controller
• Output voltage adjustable
• A the factory-set 24 V, parallel connection possible
During the warranty period, the factory-set output voltage 24 V may only be changed by
a member of the customer service department.
• Monitoring via the integrated Ethernet-CAN-module
• Facility for connecting a UPS

6. Block Circuit Diagram

7.

Dimensions

8. Connections

1 Power supply connection
2 RJ45 interface for data communication
3 Slot for SD card module (optional)
4 Connections for inputs and outputs (supplementary functions)
5 Slot for UPS power supply (optional)
6 Connection for system lines (operating voltage and CAN-Bus system; max. 32 fittings)

9. Pin Configurations

SELV-power supply and data bus (system cable)
Pin
Signal
1
24 V
2
GND
6
Level
24 V DC
0 V DC
Current
Function
3 A
Supply voltage for bus
isle looped through
Reference for bus isle
looped through