The output voltage of the 24 VDC power supply can be taken from the 4 mm safety sockets mounted on the
front side and additionally supplies the controller and the sensors connected via IO link. The output voltage
is safeguarded with a resettable fuse (4 A).
The energy consumption of the power supply and the power analyzer is determined together with the
"Output 1" connection and measured in the power analyzer with the measuring channel "L1". The energy
consumption of the outputs "Output 2" and "Output 3" is determined separately and measured with the
measurement channels "L2" and "L3".
Only operate the device in an upright position.
Power analyzer measuring channel
IL1
IL2
IL3
Subject to change
The currents to be measured are measured with current transformers with a transformer ratio of 35:1.
© Festo Didactic 8130877
Single-Phase Energy Measurement Box – Operating Instructions
Load
Energy measurement box own consumption and
OUTPUT 1 output
OUTPUT 2 output
OUTPUT 3 output
23