To set all learned atmospheric setting to full intensity, maintain the manual control on the dimmer module pressed until the lamp burns at full
intensity. When releasing the manual control push button the lamp and the indication LEDs of all corresponding push buttons will turn off.
To learn the sliders, set the learning address on C1. Operate the slider until the lamp turns on and the corresponding LED blinks rapidly. Erase a
learned slider by operating the slider until the indication LED turns off.
Quit the learning mode by resetting the dimmer module's original address.
When using firmware version 0735 you will be able to delete all push buttons and sliders saved into the memory of the dimmer module at once.
Set the address to one of the learning addresses. Maintain the manual control on the dimmer module pressed for 10 seconds. The relay will
activate and deactivate again after 7 seconds to confirm the push buttons have been erased. Set the address back to its original value.
Troubleshooting:
The dimmer module features a non-resettable fuse which will blow in case of a short-circuit or overload. In this case, return the
dimmer to the manufacturer for repair.
If the lamp does not go out due to an external cause (even after switching the power supply off and on), the control transistor
will probably be faulty. In this case, return the dimmer to the manufacturer for repair.