SAFETY INFORMATION
READ CAREFULLY BEFORE USING THE 69500 RECOVERY SYSTEM!
1. This equipment is designed to be used by qualified service personnel. The operator of this equipment must be familiar
with air conditioning and refrigeration systems. Do not attempt to operate this equipment until all safety instructions
and operating instructions are read and understood.
2. Always use eye protection (safety goggles) and hand protection (gloves) when working with refrigerants. Other types of
personal protective equipment should also be used.
3. Do not pressure test system with air. Some mixtures of air and refrigerant can be combustible or explosive.
4. READ CAREFULLY BEFORE USE OF RECOVERY/RECYCLE SYSTEM.
A) When not in use or in storage, recovery/recycle system should have a slight positive pressure in system using an
environmentally acceptable refrigerant (134a, etc.). This prevents moisture and air from contaminating the filter and
moisture indicating sight glass.
B) After every use of recycle system, oil separator must be drained. This prevents cross contamination of oil/refriger-
ants and carry over that may occur if oil separator is not empty. "Valves 9, 10, and 11" should be closed when recycle
system is not being used. See operating instructions for draining procedure of oil separator.
C) Recycle system must always be mounted vertically so that oil separator is in an up-right position with "valve
9" pointing down and "valves 10 and 11" pointing up. This is very important for the proper operation of the oil
separator and to prevent oil contamination of recycle system.
5. Recovery tank contains liquid refrigerant under high pressure. Never over fill recovery tank. Tanks should be filled to a
maximum of 80% of capacity only. Use scale only to continuously monitor the recovery tank weight. Use only approved
tanks for refrigerant recovery. An overfilled tank can explode causing serious injury or death.
6. Do not breath refrigerant vapors and/or lubricant vapor or mist. Breathing high concentrations of these substances will
cause severe health problems. Always use Recovery System in a well ventilated area.
7. This equipment is intended for use with one type refrigerant at a time until the self-purging feature is used. Mixing of
different refrigerants will cause your recovered supply of refrigerant to become contaminated.
NOTE: It is very expensive to destroy mixed or damaged refrigerants!
DANGER! – EXPLOSION RISK!!! DO NOT RECOVER FLAMMABLE REFRIGERANTS
USE OF RECOVER / RECYCLE SYSTEM
2
V5
High
V7
V4
Low
www.mastercool.com
V11
V10
V16
5
LOW
HIGH
VAC
REF
V1
V9
5
V6
SUCTION PRESSURE
CIRCUT
BREAKER
POWER
INLET
INLET
V15
V2
V3
Access
Port
34
DISCHARGE PRESSURE
LIQUID
PURGE
CLOSE
PURGE (START)
OUTLET
OUTLET
VALVE
English