Machine Features; Design - Festool EAA Manual De Instrucciones Original

Ocultar thumbs Ver también para EAA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
EAA
GB
5

Machine features

[1-1] Tool holder
[1-2] Aluminium pipe
[1-3] Permanent socket
[1-4] On/Off switch
[1-5] Socket AUTO 2
[1-6] Compressed air connection* for pneu-
matic tools, adjusted via the pressure
regulator on the maintenance unit
[1-7] Lock
[1-8] Extractor connector
[1-9] Socket AUTO 1
[1-10] Slide* for opening and closing the
extractor connector
[1-11] Unlubricated compressed air connec-
tion on EW version only*
* not on all versions included in the scope of
delivery
The illustrations specified are located at the
beginning and end of the operating manual.
6

Design

6.1
Energy box
The EAA energy box consists of two sections:
– Section containing electrical components
such as sockets and selector switches for
electric power tools (EW).
– Section containing pneumatic components,
including connections for pneumatic tools
(DW).
6.2
Versions
The different versions offer the following fea-
tures:
EAA EW CT/SRM/M
– 3 sockets, 1 non-adjustable, unlubricated
compressed air connection (not suitable
for connecting Festool compressed air
sanders!).
– Manually operated slide.
The slides are linked mechanically. Dust
can therefore only be extracted from one
machine at any one time. The slide setting
is monitored by a microswitch.
EAA EW TURBO/M
– 3 sockets, 1 non-adjustable, unlubricated
compressed air connection (not suitable
for connecting Festool compressed air
sanders!).
– Manually operated slide.
18
Dust can be extracted from two machines
at the same time. The slide setting is
monitored by a microswitch (basic posi-
tion: slide closed).
EAA EW/DW CT/SRM/M
– 3 sockets, 1 maintenance unit (pressure
regulator, condensate trap, lubricator), 2
adjustable, lubricated compressed air con-
nections, 1 non-adjustable, unlubricated
compressed air connection (not suitable
for connecting Festool compressed air
sanders!).
– Manually operated slide.
The slides are linked mechanically. Dust
can therefore only be extracted from one
machine at any one time. The slide setting
is monitored by a microswitch.
EAA EW/DW TURBO/M
– 3 sockets, 1 maintenance unit (pressure
regulator, condensate trap, lubricator), 2
adjustable, lubricated compressed air con-
nections, 1 non-adjustable, unlubricated
compressed air connection (not suitable
for connecting Festool compressed air
sanders!).
– Manually operated slide.
Dust can be extracted from two machines
at the same time. The slide setting is
monitored by a microswitch (basic posi-
tion: slide closed).
EAA EW/DW TURBO/A
– 3 sockets, 1 maintenance unit (pressure
regulator, condensate trap, lubricator), 2
adjustable, lubricated compressed air con-
nections, 1 non-adjustable, unlubricated
compressed air connection (not suitable
for connecting Festool compressed air
sanders!).
– Pneumatically operated slides
Dust can be extracted from two machines
at the same time. The slide setting is
monitored by a microswitch (basic posi-
tion: slide closed).
6.3
Conversion kits
The following conversion kits are available to
convert the EAA to a different version at a
later time:
CT/SRM/M >> TURBO/M
Modification: dust extracted by a stationary
extraction turbine instead of a mobile dust
extractor.

Publicidad

Tabla de contenido
loading