Technical Specifications - STEINEL Studioline 400 Instrucciones De Montaje

Ocultar thumbs Ver también para Studioline 400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
L400_10spr.qxd
31.07.2008
Operation
In order to switch on the
light without a heat source
in the detection zone,
switch the indoor power
switch momentarily. This
will activate the light for
the period selected.

Technical Specifications

Line voltage:
Power output:
Power consumption:
Detection angle of sensor:
Swivelling range of sensor:
ON time, adjustable:
Lighting threshold, adjustable:
Brightness setting:
Sensor range (dependent on sensor setting,
ambient temperature, and direction of approach)
From the front:
From the side:
Type of enclosure:
Ambient temperature:
13:51 Uhr
Seite 12
Weather can affect the
The Fresnel lens should be
function of the sensor light
periodically wiped clean
fixture. Strong gusts of
with a damp cloth if it gets
wind, snow, rain or hail may
dirty.
cause switching errors,
Do not use any cleaning
because the unit cannot
materials.
distinguish the sudden
change of temperature.
220 – 240 V/50 – 60 Hz
max. 60 watts (no low-energy bulbs)
1.3 W
360° all-round lens
(with 120° angle of aperture)
2 x 40° in every direction
10 sec. to 15 min.
2 – 2,000 lux
0 – 50% (Watt-o-matic)
12 m (40 ')
16 m (20 ')
IP 44, splashproof
– 25 °C to + 55 °C (– 13 °F to + 131 °F)
11