2. The over-heater protection of steam generator is adopted by ceramic temperature sensor.
3. Difference steam generators have different rated current and rated power.
4. Without the permission of our technical department, please don't enlarge the load power.
5. This product follows national standard 《 S afety of Household and similar electrical appliances 》 G B4706.1-2005
6. The installation of keyboard and electric box are attached in the appendix.
Cautions:
In order prolong the lifetime of this product and ensure the safety of human being, please read these cautions
carefully before using this product.
1. User must strictly follow our provided circuit drawing and parameter to install the load.
2. The earth wire of control box must be well connected on the circuit.
3. User must use at least 3x2mm² power supply which meet the nation standards (GB), the socket of power
supply of the control box must be at least 20A, and fix it reliably.
4. User must add extra 20A or above national standard air switch or leakage switch, the leakage switch of
control box is only used as complement.
5. Please check and ensure the pipe of water intake, steam pipe, power control box, power supply of electric
box are in good condition, then turn on the power. (Attention: Ensure that water provided)
6. The inner hole of the steam pipe should be at least 15mm, forbid to install valve on steam pipe.
7. Please don't connect electric equipment from other supplier to our steam generator. Forbid to disassemble,
refit our inside fixed wire connection.
8. The quality of water used for steam generator should meet the water standard.
9. When install the pipe of steam generator, we suggest that add the filter onto the water intake to prolong
the lifetime.
10. In hard water area, please make descaling rinsing regularly for the steam generator, especially for the
probe of the water level sensor. Normally, check it every three months. Following descaling rinsing method
is advised: Use 5-10g citric acid to dilute by 1.4L warm water, disassemble the pipe of steam output, and
infuse the diluted citric acid into the input of steam generator, then connect the pipe and wait for
60minutes to start the system, after heating for 30minutes to stop and make completely discharge.
11. Make sure that all the wires are well connected, output can't be short circuit with each other.
46