Cabina de hidromasaje
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

No Ozone
Can't receive phone
Too much noise, less
Receipt Channels
No sound
No steam comes out
from steam generator
Water inlet is running
without stopping, spout
a lot of water, but no
steam comes out.
Leak-protection switch
works
Smoke comes from
steam output, or bad
smell
5. Electric box is broken. ( Replace it)
1. The connection between Ozonizer and Electric Box is loose. ( Tighten it)
2. Output of the Ozonizer is in open circuit. ( Tighten it )
3. Output of the Ozonizer is in short circuit. (Debug short circuit)
4. Ozonizer is broken ( Replace it )
5. Electric box is broken. ( Replace it)
1. The signal wire of the telephone doesn't connect the telephone wire. ( Connect it )
2. Too many extension
3. Panel or Electric Box is broken. (Replace them)
1. The Antenna is not in a good position. ( Put it on the best position)
2. Electric box is broken. ( Replace it)
7.
The connection between Speaker and Electric Box is loose. ( Tighten it)
8.
Output of the Speaker is in open circuit. ( Tighten it )
9.
Output of the Speaker is in short circuit. (Debug short circuit)
10. Speaker is broken (Replace it )
11. Electric box is broken. ( Replace it)
9.
The Electric Heater inside the Steam Generator is broken. (Replace it)
10. The signal wire of the water inlet valve inside the Steam Generator is off or in open circuit.(Connect it)
11. The signal wire between the Electric Box and Steam Generator doesn't connect well. (Connect it)
12. The wire of the heater between Electric Box and Steam Generator doesn't connect well. (Connect it )
13. Anti-dry heating protection works. (Restore)
14. The water inlet valve is broken ( Replace it)
15. Steam Generator or Electric Box is broken. (Replace it)
1. The water level sensor loosens. (Tighten it)
2. The water inlet valve is broken. ( Replace it)
3. Steam Generator or Electric Box is broken. (Replace it)
1. Leakage of the AC220V power supply. ( Bind it)
2. Leakage of the heater inside the steam generator. ( Replace it )
3. The leak-protection switch is not good. ( Replace it )
1. Inside the Steam Generator, the water level wire is in short circuit or there is water in the level sensor.
( Debug the short circuit and dry the level sensor)
2. Steam Generator or Electric Box is broken. (Replace it)
48