INSTALLATION INSTRUCTIONS
Disassembly#
Before dismantling the air conditioner, contact a specialist. Before dismantling the
air conditioner, contact a specialist.
Noise level
•
The appliance must be installed in a place that is firm enough to avoid
increased noise and vibrations.
•
Do not place anything in front of the air outlet. Avoid increased noise levels in
this way.
•
Make sure that the hot air and noise level do not disturb neighbours.
•
Make sure that the hot air and noise level do not disturb neighbours.
Power connection
•
The appliance must be properly earthed.
•
An independent circuit must be used. A pull-out socket must not be used
because poor contact can lead to overheating or fire.
•
Do not pull too hard on the power cord.
•
A residual current circuit breaker with a leakage current below 30 mA must
exist in a fixed circuit.
•
The connection between the appliance and the power cord and the wiring
between the respective components must be in accordance with the wiring
diagram of the appliance.
•
The appliance must be wired in accordance with the national regulations for
the design of power lines.
•
The fixed connection must have a disconnecting device on the installation side
for each pole, which has a contact opening of at least 3 mm.
•
A thermo-magnetic circuit breaker must be installed in the circuit.
•
If the power cord is damaged, it must be replaced by the customer service or a
qualified electrician.
•
All electrical work must be carried out in accordance with local wiring
regulations.