PROBLEM
SPRAY WAND
LEAKS
PUMP IS NOISY
Check pump oil and engine oil level before first use of your new pressure washer.
Pump oil: Check level daily before first use of your new Power Washer. Change pump oil after first 50 hours
every year or 500 hours thereafter. Use SAE 10W-40 non foaming.
Engine oil: Check daily before first use of your new Power Washer. Change engine oil after first 20 hours
and every 100 hours thereafter. Use
Date Pump Oil
Changed
Month/Day/Year
NOTE: Read engine manual for any maintenance or service questions.
TROUBLESHOOTING
POSSIBLE CAUSE
Spray wand not properly attached
Broken o-ring
Pump is sucking air

OIL CHANGE RECORD

SAE 10W-30.
Estimated Operating
Hours Since Last
Oil Change
• 9.808-131.0 • Rev. 01/19
SOLUTION
Slide the spray wand into the gun. Turn the
wand collar clockwise onto the spray gun
threads until tight.
Call local distributor and order an o-ring.
Check that hoses and fittings are air tight.
Turn off machine and purge pump by
squeezing trigger gun until a steady flow of
water emerges through nozzle.