of the table including the collected contamination. Welding and Grinding Table is to be
securely anchored to the foundation.
Connect the outlet (outlets) to a duct system (see installation example in Figure 3).
5
Installation example
See Figure 3 and the following list.
1.
Gables possible to fold for long working objects.
2.
Regulating damper.
3.
Motor damper.
4.
Regulating damper.
5.
Motor damper.
6.
Fan Inverter.
7.
After cleaning damper.
8.
Filtermax DF 80.
9.
NCF Fan.
10.
Dust drawer.
11.
Welding and Grinding Table 1355.
12.
Welding and Grinding Table 2000.
6
Maintenance
WARNING!
Use protective goggles, breathing mask and gloves when doing service work,
specially when emptying the dust box.
Check the following points at least twice a year or when necessary.
•
Empty the dust box. Do not let it overfill. Disposal of dust should be in accordance
with local regulations.
•
Check that the outlet connection not is blocked.
•
Check that the outlet connection to the duct or motor damper is tight and secured.
6.1
Spare parts
•
Table screen, see figure 4.
Contact your nearest authorized distributor or Nederman for advice on technical
service or if you require help with spare parts. See also www.nederman.com.
Ordering spare parts
When ordering spare parts always state the following:
•
Part number and control number (see the product identification plate).
•
Detail number and name of the spare part (see www.nederman.com).
•
Quantity of the parts required.
7
Recycling
The product has been designed for component materials to be recycled. Its different
material types must be handled according to relevant local regulations. Contact the
distributor or Nederman if uncertainties arise when scrapping the product at the end of
its service life.
Welding and Grinding Table
Risk of personal injury.
EN
9