Analog Input Configuration
The following tables show the parameter settings required for various
analog input signal types.
A006
A005
00
00
01
01
00
01
02
00
01
The table below applies when the [AT] input function is not assigned to
any intelligent input terminal. The A005 setting, normally used in con-
junction with an [AT] input, is ignored.
A006
A005
00
01
02
External
Frequency
[AT]
Command
Input
OFF
[O] — [L]
ON
[OI] — [L]
OFF
[O] — [L]
ON
[O2] — [L]
OFF
[O] — [L]
ON
[OI] — [L]
OFF
[O] — [L]
ON
[O2] — [L]
OFF
[O] — [L]
ON
[OI] — [L]
OFF
[O] — [L]
ON
[O2] — [L]
External
Frequency
[AT]
Command
Input
(not
[O2] — [L]
assigned
Summation of
to any
[O] — [L] and
input
[OI] — [L]
termi-
nal)
Summation of
[O] — [L] and
[OI] — [L]
32
Trim
Frequency
Command
Input
[O2] — [L]
[O2] — [L]
[O2] — [L]
[O2] — [L]
[O2] — [L]
[O2] — [L]
Trim
Frequency
Command
Input
[O2] — [L]
[O2] — [L]
Reverse
available
(bipolar
input)
Reverse
available
(bipolar
input)