EAS ELECTRIC EDHP96 Manual De Instalación página 71

Conductos alta presión

Publicidad

function from table 2.2. Press "
parameter selection.
② After entering parameter selection, the function selection icon
lighted on; the parameter selection icon
frequency and display optional parameter code. Through pressing "
detailed parameter.
③ Press
"
"
to confirm parameter selection (details parameter codes' corresponding time refer to table 2.3).
④ After setting successfully, the function selection icon
the screen will display "Setting successfully" (as show in b part of the Fig. A). After 3 seconds will exit
optional function setting automatically, and the screen will be back to normal display. After entering optional
function setting, no operations in 5 seconds will exit function selection automatically, the setting parameter
will not change. Only press "
Table 2.1 Code of selecting the clear filter function
Function code
00
Only display, no function
01
Cleaning filter screen reminding
※ Dial code operation specification
Notes:
1. For the new series product, we can connect the indoor CCM controller via XYE port of master outdoor unit of every refrigerant
system. Notice that in this case, the outdoor unit must be set to auto addressing mode. And it will be effective after about 6
minutes.
2. To connect indoor CCM controller via XYE port of indoor unit, this wiring method is suitable for all type of indoor units, not just
for new indoor units.
3. When new indoor units and old indoor units mix connect to one refrigerant system, we can just connect the indoor CCM
controller via XYE port of indoor units. If we connect the indoor CCM controller via XYE port of master outdoor unit, the CCM
controller cannot control old indoor units.
4. If one system that connect to indoor CCM controller include 10 HP or above duct indoor unit, we recommend you set the
address of every indoor unit manually.
" and "
" key to confirm the parameter then the setting parameter will save.
Function setting
Dial code 1
Dial code 2
Dial code 3
" keys can select function, and then press "
(as show in a part of the Fig. A) will be
(as show in b part of the Fig. A) will be flashed with 1Hz
and parameter selection icon will be lighted on,
Table 2.2 Code of different times of reminding clear
Parameter code
00
01
02
03
04
Table 2.3 Dial code definition
ON
CCM30 for 3-pipes
Fahrenheit
With the optional function
71
" key to enter
" and "
" keys can select the
filter
Time (hour)
0
1250
2500
5000
10000
OFF
CCM30 for 2-pipes
Centigrade
No the optional function