4. Press the Power Button to turn the unit on. The backlit LCD Screen will display the following, indicating the unit is in Standby Mode:
The digital display will alternately show the flashing pre-set PSI value (that was last set by the Pressure Control Buttons) for 2 seconds;
then it will flash the current pressure of the item being inflated for 5 seconds (which will then light solid).
IMPORTANT: If no other actions are taken after pressing the Power Button, the unit will automatically shut off after one minute of inactivity.
5. Follow either steps 4 through 6 in the "Inflating Tires or Products With Valve Stems at Auto Mode" section or steps 4 through 5 in the
"Inflating Tires or Products With Valve Stems at Manual Mode" section.
IMPORTANT NOTE: Small items such as volleyballs, footballs, etc. inflate very rapidly. Do not over-inflate.
6. Disconnect the nozzle adapter from the inflated item.
7. Unscrew and remove the nozzle adapter from the SureFit
CAUTION: TO REDUCE THE RISK PROPERTY DAMAGE:
• Always allow the unit to cool before storing it.
• To prevent hose damage, secure the compressor hose and SureFit
• Recharge the unit fully after each use.
USING THE 2-LED AREA LIGHT
The Area Light is controlled by the Compressor. When the Compressor is turned on, the Area Light is activated. When the Compressor is
tuned off, the Area Light turns off. Press the Power Button (refer to the "Features" section to locate) to turn the Compressor and Area
Light on. Press the Power Button and hold for one second to turn the unit off. Make sure the Power Button is turned off when the unit is
being recharged or stored.
CARE AND MAINTENANCE
All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. When the unit is not in use, we
recommend that the battery is charged at least every 30 days.
Never submerge the unit in water. If the unit gets dirty, gently clean the outer surfaces of the unit with a soft cloth moistened with a mild
solution of water and detergent.
There are no user-replaceable parts. Periodically inspect the condition of adapters, connectors and wires. Contact manufacturer to replace
any components that have become worn or broken.
Battery replacement/disposal
BATTERY REPLACEMENT
The battery should last the service life of the unit. Service life is dependent on a number of factors including but not limited to the
number of recharge cycles, and proper care and maintenance of the battery by the end user. Contact manufacturer for any information
you may need.
SAFE BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of properly. Recycling is
required. Failure to comply with local, state and federal regulations can result in fines, or imprisonment.
Please recycle.
WARNINGS:
• Do not dispose of the battery in fire as this may result in an explosion.
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in
injury or fire).
• Do not expose battery to fire or intense heat as it may explode.
12V DC Charging Adapter Fuse Replacement
The fuse in the plug end of the 12V DC Charging Adapter protects the adapter's charging circuit. If the 120V AC Charging Adapter
operates, but the 12V DC Charging Adapter does not, then this fuse may be opened (blown).
TO REPLACE THE FUSE:
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 12 amp fuse.
5. Replace the fuse, spring, contact and end cap.
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12V DC Charging Adapter.
HRC120DS_ManualENSP_082517.indd 8-9
nozzle.
®
nozzle using the Storage Clips after each use.
®
8
TROUBLESHOOTING
Unit will not charge
• Make sure all of the unit's functions are turned off.
• Make sure the 120V AC Charging Adapter or 12V DC Charging Adapter is properly connected to both the unit and a functioning power
source.
• When charging using the 12V DC Charging Adapter:
– Rotate the plug slightly to assure there is good contact.
– Check that the fuse in the 12V DC Charging Adapter is not blown.
Air Compressor will not inflate
• Make sure the 120V AC Charging Adapter is disconnected. The unit cannot be operated when charging using the 120V AC Charging
Adapter.
• Make sure the Power Button is pressed to turn the unit on and that all directions in the "Using the Portable Compressor" section have
been followed exactly.
• Make sure the nozzle is securely screwed on to the valve stem when attempting to inflate tires; or that the nozzle adapter is securely
screwed into the SureFit
®
nozzle and is inserted properly into the item to be inflated on all other inflatables.
• Check that unit has a full charge. Recharge the unit if necessary.
If the unit does not charge or operate after taking the steps given above, the compressor may be damaged, contact the manufacturer at
(877) 571-2391.
LED Area Light does not come on
• Make sure the Power Button has been pressed to turn the unit on (when the Compressor is turned on, the Area Light turns on).
• Check that unit has a full charge. Recharge the unit if necessary.
ACCESSORIES
Recommended accessories for use with your tool may be available from the manufacturer. If you need assistance regarding accessories,
please contact the manufacturer at (877) 571-2391.
WARNING: The use of any accessory not recommended for use with this appliance could be hazardous.
SERVICE INFORMATION
Whether you need technical advice, repair, or genuine factory replacement parts, contact the manufacturer at (877) 571-2391.
ONE-YEAR LIMITED WARRANTY
The manufacturer warrants this product against defects in materials and workmanship for a period of ONE (1) YEAR from the date of
retail purchase by the original end-user purchaser ("Warranty Period").
If there is a defect and a valid claim is received within the Warranty Period, the defective product can be replaced or repaired in the
following ways: (1) Return the product to the manufacturer for repair or replacement at manufacturer's option. Proof of purchase may
be required by manufacturer. (2) Return the product to the retailer where product was purchased for an exchange (provided that the
store is a participating retailer). Returns to retailer should be made within the time period of the retailer's return policy for exchanges
only (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with the retailer for their specific return policy
regarding returns that are beyond the time set for exchanges.
This warranty does not apply to accessories, bulbs, fuses and batteries; defects resulting from normal wear and tear, accidents; damages
sustained during shipping; alterations; unauthorized use or repair; neglect, misuse, abuse; and failure to follow instructions for care and
maintenance for the product.
This warranty gives you, the original retail purchaser, specific legal rights and you may have other rights which vary from state to state or
province to province. This product is not intended for commercial use.
Please complete the Product Registration Card and return within 30 days from purchase of the product to: Baccus Global LLC, One City
Centre, 1 North Federal Highway, Suite 200, Boca Raton, FL 33432. Baccus Global LLC, toll-free number: (877) 571-2391.
SPECIFICATIONS
Compressor:
120 PSI maximum (3 minutes on, 30 minutes off)
Input:
12V DC, 750mA (120V AC Charging Adapter) or 1A (12V DC Charging Adapter)
Battery:
12V DC, 3 Ah, non-spillable, sealed lead-acid
DC Plug Fuse:
12A
Imported by Baccus Global LLC, One City Centre, 1 North Federal Highway, Suite 200, Boca Raton, FL 33432
www.Baccusglobal.com 1-877-571-2391
RD082517
9