Coating thickness tester / English
4.2 Replacing the Battery
• Power off the meter.
• Open the battery cover.
• Remove battery.
• Insert new battery.
• Close the battery cover.
• Caution: Make sure the anode and cathode are correctly positioned.
4.3 Menu System and Basic Settings
Press to power on; the gauge will work in measuring mode. Press Select button into MENU
mode. See following MENU system arrangement:
4.3.1 Function and operation instruction
Select Working mode
Working mode: There are 31 working modes in this gauge. Measure data would not be stored
in the gauge in Group0 measure mode.
In the other 30 working modes, 30 measured data can be stored in each mode in cycle.
A: Press Select button to enter the menu
B: Press Up/down button to select working mode
C: Press Select button to enter working mode
D: Press up/down button to select working mode
E: Press Select button for OK.
Select measure mode (Probe)
The probe can work in three modes:
AUTO: The probe can automatically select the working mode. When placed on steel (magnetic
substrates), it will work in magnetic induction principle. When placed on no-ferrous metals, it
will work in eddy current principle.
Fe: The probe works in magnetic induction principle.
No-Fe: The probe works in eddy current principle.
A: Press Select button to enter the menu
B: Press Up/down button to select working mode
C: Press Select button to enter working mode
D: Press up/down button to select working mode
E: Press Select button for OK.
4
5. Settings
5.1 Unit setting
Select unit
A: Press Select button to enter the menu
B: Press up/down button to select the setting
C: Press Select button to enter the setting
D: Press up/down button to select Unit
E: Press Select button to enter
F: Press up/down button to select
G: Press Select button for ok
5.2 Backlight setting
Adjust the brightness of the backlight.
A: Press Select button to enter the menu
B: Press up/down button to select the setting
C: Press Select button to enter the setting
D: Press up/down button to select backlight
E: Press Select button to enter
F: Press up/down button to adjust the brightness of the backlight
G: Press Back button to return.
5.3 Auto power off
You can disable Auto-power-off via MENU system or the gauge will power off automatically
in about 3 minutes if no measurement or operation.
A: Press Select button to enter the menu
B: Press up/down button to select the setting
C: Press Select button to enter the setting
D: Press up/down button to select Auto-power-off
E: Press Select button to enter
F: Press up/down button to select
G: Press Select button for ok
Coating thickness tester / English
5