Descargar Imprimir esta página

Desoutter CVI II Manual De Inicio Rápido página 9

Ocultar thumbs Ver también para CVI II:

Publicidad

Idiomas disponibles

Idiomas disponibles

ST module status
The following table is common to both ranges:
ST = Module Status
0000
Module initialisation
0001
Network / Fieldbus initialisation
0002
Module is expecting the
communication process with PLC.
0003
PLC is in Stop mode or PLC
requests module to go in IDLE
mode
0004
PLC & Module communication is
correct.
0005
Network / Fieldbus fault
0007
Fatal Error
07/2020
CVI3/CONNECT range
Main user info codes are:
232
Fieldbus module
not recognized
not a Desoutter
one
234
Fieldbus module
mismatch
6159931440
Issue no: 05
Series: -
1- The Fieldbus
module plugged in
the CVI3/CONNECT
cannot be run it is
not an authorized
Desoutter module.
2- Contact
your Desoutter
representative for
more information.
1-The Fieldbus
module declared
in configuration is
not the same that
the one present
in controller (e.g.
Profibus declared
but a Profinet
module in CVI3/
CONNECT).
9 / 36

Publicidad

loading

Este manual también es adecuado para:

Cvix iiCvi3