Roughing-In
18"
(45.7cm)
1"
(2.5cm)
8" (20.3cm)
2-1/2"
(6.4cm)
2-7/8" (7.3cm)
3" (7.6cm)
Product Information
Drop in rim style
Left drain hole, tile flange
Right drain hole, tile flange
Fixture*:
basin area
Bathing well
46" (116.8cm) x
15" (38.1cm)
water depth
To overflow
14" (35.6cm)
* Approximate measurements for comparison only.
Pump:
1 speed
Required Electrical Service
Dedicated circuit required, protected with Class A Ground Fault
Circuit Interrupter (GFCI):
Pump/control
Locate the outlet behind the whirlpool and within 24" (61cm) of the
pump.
A
1013740-1-
K-1139
60" (152.4cm)
3/8" (1cm)
K 1139
shown
K 1139 L
not shown
K 1139 R
not shown
top area
weight
55" (139.7cm) x
55 lbs.
25" (63.5cm)
(24.9kg)
capacity
57 gal. (215.8L)
HP
V
Hz
1 1/4
120
60
120V, 15A, 60 Hz
No change in measurements if connected with drain illustrated.
(K 11677 or K 11677M)
Drop in cut out
Minimum access panel
Pump/control
PUMP/CONTROL ACCESS
(IF APRON IS NOT USED)
18-1/8"
16-5/8"
(46cm)
(42.2cm)
Notes
Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of 80
lbs./square foot (390 Kg./square meter) loading.
The apron must be installed before the finish floor and wall materials are
installed.
Fixture conforms to ANSI Standard Z124.1. All dimensions are
nominal.
A
7.5
2
58 1/2" (148.6cm) x 34 1/2" (87.6cm)
20" (50.8cm) W x
required
15" (38.1cm) H
1-1/4"
(3.2cm)
TILE FLANGE
DETAIL
36" (91.4cm)
1-1/2" O.D.
1-1/2"
(3.8cm)
DROP-IN RIM
DETAIL
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-1139K-1139-lK-1139-r