At the end of the procedure, the complete calibration message is shown and the display goes to the
operation screen. Upon the next start-ups, the display will go directly to the operation screen
skipping the calibration screen.
The manual movement of the roll-up during calibration (and in manual mode, please see below) will be
blocked near the full scale of the encoder, so as to avoid calibrations at values out of scale which might
cause the roll-up to function abnormally. Hereinafter, we present the operation areas related to
the value of the encoder:
• Free movement area (encoder between 250 and 7942 points): the movement of the roll-up is free in
both directions.
• One direction inhibition area (encoder between 100 and 250 points or between 7942 and 8092 points):
the movement in the direction that caused the exceeding of limits is blocked. Therefore, if, for example,
by pressing the key + , the value of 7942 points is exceeded, this key no longer causes movement, while
the key - causes a movement which will decrease the value of the encoder.
• Total inhibition area (encoder between 0 and 100 points or between 8092 and 8192 points): the
movement of the encoder is completely blocked. The situation is reported on the display with the blinking
message "manually unlock". In this case, it will be necessary to mechanically move the roll-up after
releasing the brake.
In order to simplify any setting of the partial opening and minimum opening parameters to enable the
photocell (only roll-up), upon the calibration, it is recommended to write down the values of the encoder
corresponding to the desired positions.
Operating screen
Normally, the status of the roll-up which can undertake one of the following positions is displayed:
• open
• close
• partially opened
Instead, during the movement, the new position will be displayed:
• opening
• closing
• partial opening
In order to move the roll-up:
• Opening/closing key: starts the opening or closure of the roll-up or blocks the movement, if active; once
the active movement is blocked, the roll-up is pending a next start-up control and, in the meantime, the
automatic closure (if set up) is prohibited
• Partial opening key: partially open the roll-up, if closed; with the door partially opened, the roll-up is
completely opened; close the roll-up is partially opened
N.B : if the roll-up movement is stopped before the position is reached with the open / close key, upon
the next pressing, the movement will always be in open mode. If the emergency button is pressed, the
message "emergency stop" is displayed. If the movement is blocked with the manual stop, the message
"manual stop" is displayed.
Moreover, from this screen, the following actions are possible:
• Key + long press: access the user settings menu
38