Cold Minimum Temperature for Comfort (tcon +
This parameter shows the minimum temperature setting that can be selected in user
mode. A value between 18ºC/64ºF (default value) and 26ºC/79ºF can be assigned. The
maximum fixed limit is 30ºC.
Thermostat Battery Level (bAt)
This parameter indicates the state of the thermostat batteries, showing the level as a %
(100% is fully charged).
Slave Motorised Component (ESCL)
This parameter indicates whether a second motorised component is going to be
configured in a zone (slave motorised component). There are two possibilities:
• If a slave motorised component has been configured, it will give the option to liberate it
(LIBE option), which will free up that component.
• If no slave motorised component has been configured, it will give the option of
associating one (ASOC option). All the free motorised components in the system are
displayed and one of them must be selected (this process is similar to the one for
associating a Tacto).
Replace the Motorised Component (SUST)
This option is used to replace a motorised component which has been selected for a
zone by a different component. The previous motorised component is freed up, and a
different motorised component must be selected from the ones available in the system.
Liberate a Zone (LIbE)
This option is used to free up the motorised component or components in the zone.
Additionally, the Tacto is reset to its default values (the state it was in on leaving the
factory).
Power (of the signal) Received (POTE)
This parameter is used to check that the thermostat has sufficient coverage.
The thermostat's coverage is considered to be good if the value is over 40.
The following parameters are found only in the Master thermostat.
Maximum return temperature in Heating Mode (tret +
This parameter shows the maximum protective return temperature of the AC Unit. The
selection is between 36ºC/97ºF – 34ºC/93ºF – 32ºC/89ºF. Default temperature – 34ºC.
Minimum return temperature in Cooling Mode (tret +
This parameter shows the minimum protective return temperature of the AC Unit. The
selection is between 6ºC/42ºF – 8ºC/46ºF – 10ºC/50ºF. Default temperature – 8ºC.
Delay in closing the last motorised component (reta) (*)
This parameter indicates whether the closing of the last motorised component should be
delayed or not. By default, the last component is closed 4 seconds after the air
conditioning/heating apparatus is stopped, but there are occasions on which it is
necessary to increase this time to 3 minutes.
There are the following options:
NO: The delay is 4 seconds.
SI: The delay is 3 minutes.
Address of the System Control Unit (dirs)(*)
This parameter can be used to assign an address to each board in the configuration.
Fixed channel mode (CH16)(*)
By means of this parameter you can select the system's channel searching mode
NO: automatic search of the operating channel (by default)
SI:the channel number 16 is established as the operating channel
)
) (*)
) (*)
 